Datasheet. 9121C8001 specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2b mounting facility hole

Thread Direction
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.

RIGHT-Hand mounting facility hole

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

U-Frame

Center To Center Distance Between Mounting Facilities Parallel To Width
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.

1.000in.

Body Length
A measurement of the longest dimension of the body,in distinction from width.

1.062in.

Body Width
A measurement taken at right angles to the length of the body,in distinction from thickness.

1.375in.

Body Height
A measurement from the bottom to the top of the body,in distinction from depth.

1.250in.

Case Material
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.

steel

Case Surface Treatment
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the case.

dichromate

Inclosure Type
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.

uninclosed

Magnetic Coil Quantity
The number of magnetic coils provided.

1

Electrical Resistance
A measurement of the opposition to the flow of direct or alternating current.

113.00 ohms

Duty Type
Indicates the type of duty provided.

continuous

Terminal Location
The position of the terminal/s/ for making connection to an item.

one side

Electric Power Rating
The value of electrical energy for which the item is rated.

18.0 watts

Voltage Rating In Volts
The voltage rating at which the item is designed to operate,expressed in volts.

120.0 ac

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

2 threaded hole

Current Rating
The amount of current for which the item is designed.

245.0 milliamperes

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

32 mounting facility hole

Actuator Stroke Type
The movement of the actuator when force is applied.

pull

Linear Force Delivered
The amount of linear force delivered.

16.00 ounces

Power Takeoff Connection Type
Indicates the type of means provided for connection of the power takeoff.

U-Shaped bracket

Energizing Stroke Maximum Length
The maximum linear travel from the de-energized to the energized position.

0.375in.

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.190in. mounting facility hole ⁓13/64"

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

two position IN-Line

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unf mounting facility hole

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

2 tab, solder lug

Answers.

What class is the thread series?

Unf mounting facility hole

What is the thread quantity per inch?

32 mounting facility hole

What is the thread direction?

Right-hand mounting facility hole

What is the thread class?

2b mounting facility hole

What is the NSN for 9121C8001?

5945-01-119-0995

How is this classified for shipping?

Schedule B number: 8412909080
nmfc 063100
Parts of engines and motors

What's the federal classification of 9121C8001?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-119-0995 SOLENOID,ELECTRICAL

unf mounting facility hole thread series 32 mounting facility hole thread quantity per inch right-hand mounting facility hole 2b mounting facility hole thread class

NIIN
011190995
NIIN Date
09/17/81
Schedule B
8412909080 
Name Code
00310
FIIG
A134A0
Item Weight
12.000lbs
Item Dimensions
--
QUP
 
Historical Price
$132.88 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. C9-2000-1 Cage 73662

Major End Users Countries and entities

  • - Defense Logistics Agency 
  • - Republic of Korea 
  • - Turkey 

Availability for 9121C8001 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
063100 SOLENOIDS/PARTS W/WO ARMATURES 
UFC (universal freight code)
35185 

Similar by Design Other solenoids with similar characteristics

Nothing similar to this part number was found in our inventory

9121C8001 / Solenoid,electricalWhat is the formal definition of this item?

An item consisting of one or more coils surrounding an iron core. the coil(s) and the core are moveable in relation to each other. the axial or rotary movement is a result of the magnetic flux of the coil. it is designed to convert electrical energy into mechanical energy. it does not include switch contacts. see also relay, electromagnetic, and electromagnetic actuator.