5267517-001

5267517001 Electrical Solenoid

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 5267517-001 specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2b mounting facility hole

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

cylindrical frame

Body Diameter
The length of a straight line which passes through the center of the body,and terminates at the circumference.

1.400in. and 1.510in.

Body Length
A measurement of the longest dimension of the body,in distinction from width.

1.470in. and 1.530in.

Maximum Operating Temp
The maximum temperature at which the item is rated to operate for an extended period of time.

122.0 deg fahrenheit

Actuator Length
The measurement of the distance that the actuator protrudes from the body.

0.990in. and 1.010in.

Fragility Factor
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.

moderately rugged

Actuator Diameter
The length of a straight line which passes through the center of the actuator,and terminates at the circumference.

0.740in. and 0.760in.

Inclosure Type
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.

fully inclosed

Magnetic Coil Quantity
The number of magnetic coils provided.

1

Electrical Resistance
A measurement of the opposition to the flow of direct or alternating current.

28.90 ohms and 35.40 ohms

Duty Type
Indicates the type of duty provided.

continuous

Terminal Location
The position of the terminal/s/ for making connection to an item.

end opposite actuator

Electric Power Rating
The value of electrical energy for which the item is rated.

290.0 watts

Voltage Rating In Volts
The voltage rating at which the item is designed to operate,expressed in volts.

100.0 dc

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

1 threaded hole

Storage Type
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.

general purpose warehouse

Actuator Stroke Type
The movement of the actuator when force is applied.

pull

Linear Force Delivered
The amount of linear force delivered.

20.00 pounds

Power Takeoff Connection Type
Indicates the type of means provided for connection of the power takeoff.

SLOTTED-Drilled

Energizing Stroke Maximum Length
The maximum linear travel from the de-energized to the energized position.

0.200in.

Power Takeoff Connection Hole Diameter
The length of a straight line which passes through the center of a power takeoff connection hole,and terminates at the circumference.

0.155in. and 0.161in.

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.250in. mounting facility hole ⁓1/4"

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

single position

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unf mounting facility hole

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

2 wire lead

Answers.

What quantity is this sold in?

1EA

What class is the thread series?

Unf mounting facility hole

What is the thread class?

2b mounting facility hole

What is the NSN for 5267517-001?

5945-01-293-2451

How is this classified for shipping?

Schedule B number: 8412909080
nmfc 063100
Parts of engines and motors

What's the federal classification of 5267517-001?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-293-2451 SOLENOID,ELECTRICAL

unf mounting facility hole thread series 2b mounting facility hole thread class

NIIN
012932451
NIIN Date
01/29/89
Schedule B
8412909080 
Name Code
00310
FIIG
A134A0
Item Weight
1.000lbs
Item Dimensions
15 X 15 X 25
QUP
Historical Price
$824.63 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. L-12-A-M2-L-E2-100-P-12 Cage 81983

Major End Users Countries and entities

  • - Department of The Navy 

Availability for 5267517-001 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
063100 SOLENOIDS/PARTS W/WO ARMATURES 
UFC (universal freight code)
35185 

Similar by Design Other solenoids with similar characteristics

Nothing similar to this part number was found in our inventory

5267517-001 / Solenoid,electricalWhat is the formal definition of this item?

An item consisting of one or more coils surrounding an iron core. the coil(s) and the core are moveable in relation to each other. the axial or rotary movement is a result of the magnetic flux of the coil. it is designed to convert electrical energy into mechanical energy. it does not include switch contacts. see also relay, electromagnetic, and electromagnetic actuator.