43-3175-0

4331750 Electrical Solenoid

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 43-3175-0 specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2b mounting facility hole

Thread Direction
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.

RIGHT-Hand mounting facility hole

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

enclosed frame

Center To Center Distance Between Mounting Facilities Parallel To Length
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.

0.880in.

Center To Center Distance Between Mounting Facilities Parallel To Width
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.

0.880in.

Body Length
A measurement of the longest dimension of the body,in distinction from width.

2.480in.

Body Width
A measurement taken at right angles to the length of the body,in distinction from thickness.

1.240in.

Body Height
A measurement from the bottom to the top of the body,in distinction from depth.

2.250in.

Inclosure Type
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.

fully inclosed

Magnetic Coil Quantity
The number of magnetic coils provided.

1

Electrical Resistance
A measurement of the opposition to the flow of direct or alternating current.

13.92 ohms

Duty Type
Indicates the type of duty provided.

continuous

Terminal Location
The position of the terminal/s/ for making connection to an item.

one side

Electric Power Rating
The value of electrical energy for which the item is rated.

110.0 watts

Voltage Rating In Volts
The voltage rating at which the item is designed to operate,expressed in volts.

12.0 dc

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

2 threaded hole

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

32 mounting facility hole

Actuator Stroke Type
The movement of the actuator when force is applied.

pull

Power Takeoff Connection Type
Indicates the type of means provided for connection of the power takeoff.

U-Shaped bracket

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.190in. mounting facility hole ⁓13/64"

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

two position diagonal

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unf mounting facility hole

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

2 tab, solder lug

Answers.

What quantity is this sold in?

1EA

What class is the thread series?

Unf mounting facility hole

What is the thread quantity per inch?

32 mounting facility hole

What is the thread direction?

Right-hand mounting facility hole

What is the thread class?

2b mounting facility hole

What is the NSN for 43-3175-0?

5945-01-180-5417

How is this classified for shipping?

Schedule B number: 8412909080
nmfc 063100
Parts of engines and motors

What's the federal classification of 43-3175-0?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-180-5417 SOLENOID,ELECTRICAL

unf mounting facility hole thread series 32 mounting facility hole thread quantity per inch right-hand mounting facility hole 2b mounting facility hole thread class

NIIN
011805417
NIIN Date
05/30/84
Schedule B
8412909080 
Name Code
00310
FIIG
A134A0
Item Weight
0.000lbs
Item Dimensions
--
QUP
Historical Price
$131.83 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 16-8-433175 Cage 62812
2. SHA2601-1 Cage 02289

Major End Users Countries and entities

  • - Department of The Army 

Availability for 43-3175-0 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
063100 SOLENOIDS/PARTS W/WO ARMATURES 
UFC (universal freight code)
35185 

Similar by Design Other solenoids with similar characteristics

Nothing similar to this part number was found in our inventory

43-3175-0 / Solenoid,electricalWhat is the formal definition of this item?

An item consisting of one or more coils surrounding an iron core. the coil(s) and the core are moveable in relation to each other. the axial or rotary movement is a result of the magnetic flux of the coil. it is designed to convert electrical energy into mechanical energy. it does not include switch contacts. see also relay, electromagnetic, and electromagnetic actuator.