Datasheet. 20791-102-5 specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2a all facilities all locations

Thread Direction
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.

RIGHT-Hand all facilities all locations

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

enclosed frame

Body Length
A measurement of the longest dimension of the body,in distinction from width.

1.880in.

Body Width
A measurement taken at right angles to the length of the body,in distinction from thickness.

1.250in.

Case Material
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.

any acceptable

Case Surface Treatment
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the case.

any acceptable

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

any acceptable

Actuator Diameter
The length of a straight line which passes through the center of the actuator,and terminates at the circumference.

0.125in.

Inclosure Type
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.

fully inclosed

Magnetic Coil Quantity
The number of magnetic coils provided.

1

Duty Type
Indicates the type of duty provided.

continuous

Terminal Location
The position of the terminal/s/ for making connection to an item.

end opposite actuator

Voltage Rating In Volts
The voltage rating at which the item is designed to operate,expressed in volts.

24.0 dc

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

1 connector

Current Rating
The amount of current for which the item is designed.

6.5 amperes

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

40 all facilities all locations

Actuator Stroke Type
The movement of the actuator when force is applied.

pull

Linear Force Delivered
The amount of linear force delivered.

9.00 pounds

Power Takeoff Connection Type
Indicates the type of means provided for connection of the power takeoff.

external threads

Energizing Stroke Maximum Length
The maximum linear travel from the de-energized to the energized position.

0.250in.

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.112in. all facilities all locations ⁓1/8"

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unc all facilities all locations

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

1 connector, receptacle

Answers.

What quantity is this sold in?

1EA

What class is the thread series?

Unc all facilities all locations

What is the thread quantity per inch?

40 all facilities all locations

What is the thread direction?

Right-hand all facilities all locations

What is the thread class?

2a all facilities all locations

What is the NSN for 20791-102-5?

5945-00-937-0594

How is this classified for shipping?

Schedule B number: 8412909080
nmfc 063100
Parts of engines and motors

What's the federal classification of 20791-102-5?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-00-937-0594 SOLENOID,ELECTRICAL

unc all facilities all locations thread series 40 all facilities all locations thread quantity per inch right-hand all facilities all locations 2a all facilities all locations thread class

NIIN
009370594
NIIN Date
11/02/66
Schedule B
8412909080 
Name Code
00310
FIIG
A134A0
Item Weight
0.000lbs
Item Dimensions
--
QUP
Historical Price
$656.80 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Major End Users Countries and entities

  • - Defense Logistics Agency 

Availability for 20791-102-5 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
063100 SOLENOIDS/PARTS W/WO ARMATURES 
UFC (universal freight code)
35185 

Similar by Design Other solenoids with similar characteristics

Nothing similar to this part number was found in our inventory

20791-102-5 / Solenoid,electricalWhat is the formal definition of this item?

An item consisting of one or more coils surrounding an iron core. the coil(s) and the core are moveable in relation to each other. the axial or rotary movement is a result of the magnetic flux of the coil. it is designed to convert electrical energy into mechanical energy. it does not include switch contacts. see also relay, electromagnetic, and electromagnetic actuator.