1502-12A6G1-BS1

150212A6G1BS1 Electrical Solenoid

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 1502-12A6G1-BS1 specification

Thread Class
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.

2b power takeoff facility hole

Thread Direction
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.

RIGHT-Hand power takeoff facility hole

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

cylindrical frame

Center To Center Distance Between Mounting Facilities Parallel To Length
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.

2.500in.

Body Diameter
The length of a straight line which passes through the center of the body,and terminates at the circumference.

1.500in.

Body Length
A measurement of the longest dimension of the body,in distinction from width.

3.400in.

Environmental Protection
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.

any acceptable

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.280in.

Maximum Operating Temp
The maximum temperature at which the item is rated to operate for an extended period of time.

250.0 deg fahrenheit

Mounting Base Width
A measurement taken at right angles to the length of the mounting base,in distinction from thickness.

3.000in.

Fragility Factor
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.

moderately rugged

Inclosure Type
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.

fully inclosed

Magnetic Coil Quantity
The number of magnetic coils provided.

2

Duty Type
Indicates the type of duty provided.

continuous

Terminal Location
The position of the terminal/s/ for making connection to an item.

end opposite actuator

Voltage Rating In Volts
The voltage rating at which the item is designed to operate,expressed in volts.

12.0 dc

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

2 unthreaded hole

Storage Type
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.

general purpose warehouse

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

28 power takeoff facility hole

Actuator Stroke Type
The movement of the actuator when force is applied.

pull

Linear Force Delivered
The amount of linear force delivered.

9.00 pounds

Power Takeoff Connection Type
Indicates the type of means provided for connection of the power takeoff.

internal threads

Energizing Stroke Maximum Length
The maximum linear travel from the de-energized to the energized position.

1.000in.

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.250in. power takeoff facility hole ⁓1/4"

Mounting Facility Pattern
The general configuration and relative position of the facilities provided for mounting the item.

two position IN-Line

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unf power takeoff facility hole

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

2 screw

Answers.

What class is the thread series?

Unf power takeoff facility hole

What is the thread quantity per inch?

28 power takeoff facility hole

What is the thread direction?

Right-hand power takeoff facility hole

What is the thread class?

2b power takeoff facility hole

What is the NSN for 1502-12A6G1-BS1?

5945-01-239-6533

How is this classified for shipping?

Schedule B number: 8412909080
Parts of engines and motors

What's the federal classification of 1502-12A6G1-BS1?

FSC 5945 ⁓ Relays and solenoids

Excluding contractors.

NSN 5945-01-239-6533 SOLENOID,ELECTRICAL

unf power takeoff facility hole thread series 28 power takeoff facility hole thread quantity per inch right-hand power takeoff facility hole 2b power takeoff facility hole thread class

NIIN
012396533
NIIN Date
09/01/86
Schedule B
8412909080 
Name Code
00310
FIIG
A134A0
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Major End Users Countries and entities

  • - Canada 

Availability for 1502-12A6G1-BS1 A member of our team will provide you with a price and availability quote

Request a Quote »

Similar by Design Other solenoids with similar characteristics

Nothing similar to this part number was found in our inventory

1502-12A6G1-BS1 / Solenoid,electricalWhat is the formal definition of this item?

An item consisting of one or more coils surrounding an iron core. the coil(s) and the core are moveable in relation to each other. the axial or rotary movement is a result of the magnetic flux of the coil. it is designed to convert electrical energy into mechanical energy. it does not include switch contacts. see also relay, electromagnetic, and electromagnetic actuator.