Serving our customers with quality and safety first.
MULTIPOLE-Multiple actuator type
2.000in.
2.265in.
plastic
1.750in.
0.750in.
1.666in.
0.750in.
metering panel model 34-063
0.130in.
2.000in.
3
6 threaded hole
12.096 cubicin.
37.5 amperes ac all locations and 37.5 amperes dc all locations
250.0 ac all locations
38.0 ac all locations
overcurrent all locations
magnetic all locations
time delay all locations
126.0 all locations
manual
trip free
series trip all locations
0.138in. ⁓9/64"
1.000 at 150 pct all locations
400.0 all locations
6.600 ounces
unc
6 quick disconnect, male
Unc
Schedule B number: 8536200040
Automatic circuit breakers, for a voltage not exceeding 1,000 v
FSC 5925 ⁓ Circuit breakers
Excluding relays.
Used on metering panel model 34-063. unc thread series
1. | 29-1029 | Cage 91723 |
Nothing similar to this part number was found in our inventory
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.