NFNLE36100 Circuit Breaker

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. NFNLE36100 specification

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

MULTIPOLE-Multiple actuator type

Case Material
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.

plastic

End Item Identification
The national stock number or the identification information of the end equipment for which the item is a part.

120v 400hz mission bay power panel N2 main electrical assembly

Pole Quantity
The number of poles included in the item.

3

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

4 unthreaded hole

Maximum Continuous Load Current Rating Per Pole
The maximum current load that each pole is rated to carry continuously.

100.0 amperes ac all locations

Operating Voltage Type And Rating Per Pole In Volts
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.

600.0 ac all locations and 690.0 ac all locations

Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.

25000.0 ac all locations

Circuit Protection Type
Indicates the type of electrical condition that will cause the device to trip.

overcurrent all locations

Trip Release Method
The means by which the trip mechanism is released.

THERMAL-Magnetic all locations

Reset Method
The means provided to reposition the mechanism so that the device is ready to function.

manual

Part Name Assigned By Controlling Agency
The name assigned to the item by the government agency or commercial organization controlling the design of the item.

breaker, 3 pole, 100 amp

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

3 poles, 2 trip

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

50.0 all locations or 60.0 all locations

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

6 tab, solder lug

Answers.

What quantity is this sold in?

1EA

What is the NSN for NFNLE36100?

5925-01-566-7676

How is this classified for shipping?

Schedule B number: 8536200040
nmfc 061300
Automatic circuit breakers, for a voltage not exceeding 1,000 v

What's the federal classification of NFNLE36100?

FSC 5925 ⁓ Circuit breakers

Excluding relays.

NSN 5925-01-566-7676 CIRCUIT BREAKER

Used on 120v 400hz mission bay power panel n2 main electrical assembly. 3 poles, 2 trip breaker, 3 pole, 100 amp

NIIN
015667676
NIIN Date
09/09/08
Schedule B
8536200040 
Name Code
00136
FIIG
A030A0
Item Weight
0.000lbs
Item Dimensions
QUP
Historical Price
$1,414.90 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 10310-1EA1201-12 SEQ. NO.65 Cage 47750
2. BRE4110 Cage 47750
3. HGL36100 Cage 56365
4. HDL36100 Cage 56365

Major End Users Countries and entities

  • - Department of The Navy 

Availability for NFNLE36100 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other circuit breakers with similar characteristics

Nothing similar to this part number was found in our inventory

NFNLE36100 / Circuit breakerWhat is the formal definition of this item?

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.