Serving our customers with quality and safety first.
single pole type
0.187in. and 0.249in.
2.189in.
0.760in.
metal
1.190in.
1.800in. and 1.820in.
moderately rugged
2.370in.
1
2 threaded hole
general purpose warehouse
magnetic
32
10.0 amperes ac single location and 10.0 amperes dc single location
200.0 ac single location and 28.0 dc single location
5000.0 ac single location and 5000.0 dc single location
overcurrent single location
magnetic single location
time delay single location
138.0 single location
manual
trip free
1 PUSH-Pull
TRIP-Reset
at pole one
relay trip single location
0.138in. ⁓9/64"
18.000 at 200 pct single location and 42.0000 at 200 pct single location
corrosion resistant and hermetically sealed and explosion proof and humidity resistant and salt spray proof and sand resistant and dustproof and vibrationproof and shock resistant and fungus resistant
amperes rating v; circuit breaker must meet vibration test for jet powered aircraft
400.0 single location
0.200 pounds
81349-MIL-C-27715 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
unc
2 tab w/screw
96906-MS24571 government standard
1EA
Unc
32
Schedule B number: 8536200040
nmfc 061300
Automatic circuit breakers, for a voltage not exceeding 1,000 v
FSC 5925 ⁓ Circuit breakers
Excluding relays.
unc thread series amperes rating v; circuit breaker must meet vibration test for jet powered aircraft 32 thread quantity per inch
1. | MIL-DTL-27715 | Cage 81349 |
2. | 6752-12-10 | Cage 82647 |
3. | MIL-C-27715 | Cage 81349 |
Nothing similar to this part number was found in our inventory
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.