MP705

MP705 Circuit Breaker

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. MP705 specification

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

single pole type

Bushing Length
A measurement of the longest dimension of a bushing,in distinction from width.

0.235in. and 0.265in.

Body Length
A measurement of the longest dimension of the body,in distinction from width.

1.078in. and 1.108in.

Body Width
A measurement taken at right angles to the length of the body,in distinction from thickness.

0.750in.

Case Material
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.

plastic

Center To Center Distance Between Terminals Parallel To Length
The center to center distance between terminals parallel to the length of the item.

0.689in. and 0.719in.

Fragility Factor
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.

moderately rugged

Mounting Surface To Terminal End Distance

1.812in.

Pole Quantity
The number of poles included in the item.

1

Arc Quenching Method
The means of quenching an arc.

air

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

1 threaded bushing

Storage Type
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.

general purpose warehouse

Special Handling Feature
The unusual or unique characteristic/s/ or quality/ies/ of an item which necessitates the establishment of a requirement for special handling.

magnetic

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

32

Maximum Continuous Load Current Rating Per Pole
The maximum current load that each pole is rated to carry continuously.

20.0 amperes ac single location and 20.0 amperes dc single location

Operating Voltage Type And Rating Per Pole In Volts
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.

120.0 ac single location and 28.0 dc single location

Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.

6000.0 ac single location and 6000.0 dc single location

Circuit Protection Type
Indicates the type of electrical condition that will cause the device to trip.

overcurrent single location

Trip Release Method
The means by which the trip mechanism is released.

magnetic single location

Trip Release Characteristic
Denotes the type of trip release action.

instantaneous single location

Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.

125.0 single location

Reset Method
The means provided to reposition the mechanism so that the device is ready to function.

manual

Main Contact Tripping Mechanism Type
Indicates the type of mechanism provided for tripping main contacts.

trip free

Manual Actuator Type And Quantity
Indicates the type and number of actuators provided for manual control.

1 push button

Actuator Function
Denotes the action imparted by actuator operation.

TRIP-Reset

Actuator Position Designation
An indication of the designated position of the actuator.

at pole one

Internal Trip Release Configuration
The basic internal electrical configuration of the trip mechanism.

series trip single location

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.469in. ⁓15/32"

Inclosure Protection Type For Which Designed
Indicates the type of protection for which the inclosure is designed.

explosion proof

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

60.0 single location

Unpackaged Unit Weight
The measured weight of an item unencumbered by packaging or packing material.

1.500 ounces

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

uns

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

2 tab w/screw

Answers.

What class is the thread series?

Uns

What is the thread quantity per inch?

32

What is the NSN for MP705?

5925-00-591-2792

How is this classified for shipping?

Schedule B number: 8536200040
nmfc 061300
Automatic circuit breakers, for a voltage not exceeding 1,000 v

What's the federal classification of MP705?

FSC 5925 ⁓ Circuit breakers

Excluding relays.

NSN 5925-00-591-2792 CIRCUIT BREAKER

uns thread series 32 thread quantity per inch

NIIN
005912792
NIIN Date
01/01/63
Schedule B
8536200040 
Name Code
00136
FIIG
A030A0
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. MP705D Cage 76374
2. 700-029-20 Cage 76374
3. 613540-9 Cage 98897

Major End Users Countries and entities

  • - Italy 

Availability for MP705 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other circuit breakers with similar characteristics

Nothing similar to this part number was found in our inventory

MP705 / Circuit breakerWhat is the formal definition of this item?

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.