Serving our customers with quality and safety first.
MULTIPOLE-Multiple actuator type
0.235in. and 0.265in.
2.235in. and 2.265in.
2.407in. and 2.437in.
plastic
0.450in. and 0.640in.
0.735in. and 0.765in.
moderately rugged
1.813in.
3
3 threaded bushing
general purpose warehouse
32
20.0 amperes ac all locations and 20.0 amperes dc all locations
120.0 ac all locations and 30.0 dc all locations
3500.0 ac all locations and 6000.0 dc all locations
overcurrent all locations
thermal all locations
time delay all locations
138.0 all locations
manual
trip free
3 PUSH-Pull
TRIP-Reset
at each pole
one, two, and three linked
series trip all locations
0.469in. ⁓15/32"
15.000 at 200 pct all locations and 55.000 at 200 pct all locations
shock resistant and vibration resistant
25.0 deg celsius all locations
400.0 all locations
0.330 pounds
76374-MP-714 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
uns
6 tab w/screw
1EA
Uns
32
Schedule B number: 8536200040
nmfc 061300
Automatic circuit breakers, for a voltage not exceeding 1,000 v
FSC 5925 ⁓ Circuit breakers
Excluding relays.
uns thread series 32 thread quantity per inch
Nothing similar to this part number was found in our inventory
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.