Datasheet. M83383/01-02 specification

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

rectangular dimensional envelope

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

2.250in. ⁓2-1/4"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

4.260in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

1.256in.

Case Material
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.

plastic

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.172in.

Pole Quantity
The number of poles included in the item.

1

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

2 unthreaded hole

Maximum Continuous Load Current Rating Per Pole
The maximum current load that each pole is rated to carry continuously.

7.5 amperes ac single location and 7.5 amperes dc single location

Operating Voltage Type And Rating Per Pole In Volts
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.

115.0 ac single location and 28.0 dc single location

Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.

3600.0 ac single location and 3600.0 dc single location

Circuit Protection Type
Indicates the type of electrical condition that will cause the device to trip.

overcurrent single location

Trip Release Method
The means by which the trip mechanism is released.

thermal single location

Trip Release Characteristic
Denotes the type of trip release action.

time delay single location

Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.

1000.0 single location

Reset Method
The means provided to reposition the mechanism so that the device is ready to function.

automatic

Internal Trip Release Configuration
The basic internal electrical configuration of the trip mechanism.

series trip single location

Trip Delay Time In Seconds Per Rated Continuous Current
The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.

11.000 at 800 pct pascal single location and 40.000 18 stage pascal single location

Trip Release Ambient Temp Rating
The temperature of the medium surrounding the trip release at which it can be operated continuously.

-54.0 deg celsius single location and 71.0 deg celsius single location

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

400.0 single location

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

2 threaded stud

Answers.

What is the overall width?

1.256 inches maximum

What is the NSN for M83383/01-02?

5925-01-592-2356

How is this classified for shipping?

Schedule B number: 8536200040
Automatic circuit breakers, for a voltage not exceeding 1,000 v

What's the federal classification of M83383/01-02?

FSC 5925 ⁓ Circuit breakers

Excluding relays.

NSN 5925-01-592-2356 CIRCUIT BREAKER

1.256" overall width 2.250" overall length

NIIN
015922356
NIIN Date
02/28/11
Schedule B
8536200040 
Name Code
00136
FIIG
A030A0
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. MIL-PRF-83383/01 Cage 81349
2. MIL-PRF-83383/01 Cage 81349

Major End Users Countries and entities

  • - United Kingdom 

Availability for M83383/01-02 A member of our team will provide you with a price and availability quote

Request a Quote »

Similar by Design Other circuit breakers with similar characteristics

Nothing similar to this part number was found in our inventory

M83383/01-02 / Circuit breakerWhat is the formal definition of this item?

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.