Serving our customers with quality and safety first.
MULTIPOLE-Single actuator type
0.464in. and 0.526in.
1.969in. and 2.031in.
2.265in.
plastic
1.499in. and 1.561in.
0.735in. and 0.765in.
at 3 oclock and at 9 oclock and at 12 oclock
0.641in. and 0.671in.
0.115in. and 0.145in.
0.138in.
single pole, double throw
moderately rugged
1430-01-087-6330
2.232in.
3
magnetic blowout
1 threaded bushing w/panel seal
general purpose warehouse
magnetic
32
30.0 amperes ac all locations
240.0 ac all locations
1000.0 ac all locations
overcurrent all locations
magnetic all locations
time delay all locations
150.0 all locations
manual
trip free
1 toggle
TRIP-Reset
at pole two
1 alarm
series trip all locations
0.500in. ⁓1/2"
internal at pole one
20.000 at 200 pct all locations and 160.000 at 200 pct all locations
fungus resistant
tab, solder lug
10.0 ac and 2.0 dc
250.0 ac and 50.0 dc
400.0 all locations
81349-MIL-C-55629 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
un
6 tab w/screw
81349-MIL-C-55629/22 government specification
1EA
Un
32
Schedule B number: 8536200040
nmfc 061300
Automatic circuit breakers, for a voltage not exceeding 1,000 v
FSC 5925 ⁓ Circuit breakers
Excluding relays.
Used on 1430-01-087-6330. un thread series 32 thread quantity per inch
1. | MIL-PRF-55629/22 | Cage 81349 |
2. | MIL-C-55629/22 | Cage 81349 |
3. | MIL-PRF-55629/22 | Cage 81349 |
4. | MIL-C-55629/22 | Cage 81349 |
Nothing similar to this part number was found in our inventory
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.