Serving our customers with quality and safety first.
MULTIPOLE-Multiple actuator type
1.562in.
1.281in.
plastic
0.950in.
0.625in.
double pole, single throw, normally closed
los angeles class ssn (688) , ship control station, enclosure assembly mini station, mode select console
1.950in.
2
2 threaded hole
10
5.0 amperes ac all locations and 5.0 amperes dc all locations
240.0 ac all locations and 50.0 dc all locations
50.0 ac all locations
overcurrent all locations
magnetic all locations
time delay all locations
800.0 all locations
manual
trip free
1 toggle
TRIP-Reset
at each pole
one and two linked
series trip all locations
0.138in. ⁓9/64"
external between pole one and two
fungus resistant and moisture resistant and salt water resistant
tab w/screw
5.0 ac
240.0 ac
circuit breaker
400.00 all locations
unc
4 screw
1EA
Unc
10
Schedule B number: 8536200040
nmfc 061300
Automatic circuit breakers, for a voltage not exceeding 1,000 v
FSC 5925 ⁓ Circuit breakers
Excluding relays.
Used on los angeles class ssn (688), ship control station, enclosure assembly mini station, mode select console. unc thread series circuit breaker 10 thread quantity per inch
1. | MIL-PRF-39019/4 | Cage 81349 |
2. | 569-7067768-199 | Cage 53711 |
3. | 569-7067768-383 | Cage 53711 |
4. | 569-7067768-652 | Cage 53711 |
5. | H677-2201-199 | Cage 96169 |
6. | H677-2201-383 | Cage 96169 |
7. | H677-2201-652 | Cage 96169 |
8. | 7067768 | Cage 53711 |
Nothing similar to this part number was found in our inventory
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.