Serving our customers with quality and safety first.
single pole type
0.332in. and 0.380in.
1.531in. and 1.562in.
0.594in. and 0.625in.
metal
0.875in. and 0.906in.
single pole, double throw
moderately rugged
1.669in. and 1.700in.
1
1 threaded bushing w/panel seal
general purpose warehouse
magnetic
high inrush protection
32
1.0 amperes ac single location and 1.0 amperes dc single location
240.0 ac single location and 50.0 dc single location
300.0 ac single location and 500.0 dc single location
overcurrent single location
magnetic single location
time delay single location
125.0 single location
manual
trip free
1 toggle
TRIP-Reset
at pole one
1 alarm
series trip single location
0.375in. ⁓3/8"
internal at pole one
0.055 at 200 pct single location and 0.950 at 200 pct single location
fungus resistant and hermetically sealed
tab, solder lug
0.5 ac and 0.5 dc
120.0 ac and 50.0 dc
400.0 single location
50.0 grams
81349-MIL-C-39019 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
unef
2 wire hook
81349-MIL-C-39019/2 government specification
1EA
Unef
32
Schedule B number: 8536200040
nmfc 061300
Automatic circuit breakers, for a voltage not exceeding 1,000 v
FSC 5925 ⁓ Circuit breakers
Excluding relays.
unef thread series 32 thread quantity per inch
1. | MIL-C-39019/2 | Cage 81349 |
2. | 1691AS280 | Cage 30003 |
3. | 1691AS280 | Cage 30003 |
4. | 1691AS280 | Cage 30003 |
5. | MIL-C-39019/2 | Cage 81349 |
6. | 1691AS280 | Cage 30003 |
7. | MIL-C-39019/2 | Cage 81349 |
8. | 1691AS280 | Cage 30003 |
9. | MIL-C-39019/2 | Cage 81349 |
10. | 1691AS280 | Cage 30003 |
Nothing similar to this part number was found in our inventory
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.