M39019-2-12

M39019212 Circuit Breaker

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. M39019-2-12 specification

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

single pole type

Bushing Length
A measurement of the longest dimension of a bushing,in distinction from width.

0.280in. and 0.380in.

Body Length
A measurement of the longest dimension of the body,in distinction from width.

1.562in.

Body Width
A measurement taken at right angles to the length of the body,in distinction from thickness.

0.625in.

Case Material
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.

metal

Center To Center Distance Between Terminals Parallel To Length
The center to center distance between terminals parallel to the length of the item.

0.906in.

Switch Contact Arrangement
A designation that describes the basic electrical configuration of a switch.

single pole, double throw

Mounting Surface To Terminal End Distance

1.700in.

Pole Quantity
The number of poles included in the item.

1

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

1 threaded bushing

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

32

Maximum Continuous Load Current Rating Per Pole
The maximum current load that each pole is rated to carry continuously.

500.0 milliamperes dc single location

Operating Voltage Type And Rating Per Pole In Volts
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.

50.0 dc single location

Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.

500.0 dc single location

Circuit Protection Type
Indicates the type of electrical condition that will cause the device to trip.

overcurrent single location

Trip Release Method
The means by which the trip mechanism is released.

magnetic single location

Trip Release Characteristic
Denotes the type of trip release action.

time delay single location

Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.

125.0 single location

Ultimate Trip Time Per Pole In Seconds
The ultimate time per pole in which the device must trip,expressed in seconds.

3.000 single location and 60.000 single location

Reset Method
The means provided to reposition the mechanism so that the device is ready to function.

manual

Main Contact Tripping Mechanism Type
Indicates the type of mechanism provided for tripping main contacts.

trip free

Manual Actuator Type And Quantity
Indicates the type and number of actuators provided for manual control.

1 toggle

Actuator Function
Denotes the action imparted by actuator operation.

TRIP-Reset

Actuator Position Designation
An indication of the designated position of the actuator.

at pole one

Auxiliary Switch Function And Quantity
The function for which the auxiliary switch is designed and the number provided.

1 alarm

Internal Trip Release Configuration
The basic internal electrical configuration of the trip mechanism.

series trip single location

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.375in. ⁓3/8"

Switch Location And Position Designation
Indicates the location of the switch in relation to its designated position.

internal at pole one

Trip Delay Time In Seconds Per Rated Continuous Current
The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.

0.500 at 200 pct single location and 9.000 at 200 pct single location and 1.750 at 400 pct single location

Inclosure Protection Type For Which Designed
Indicates the type of protection for which the inclosure is designed.

fungus resistant

Switch Terminal Type
Indicates the type of terminal for providing electrical connection to the switch.

tab, solder lug

Switch Current Rating And Type In Amps
The amount of current,expressed in amperes,and the type for which the switch is rated.

0.5 ac and 0.5 dc

Switch Voltage Rating And Type In Volts
The voltage,expressed in volts,and current type for which the switch is rated.

120.0 ac and 50.0 dc

Test Data Document
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.

81349-MIL-C-39019 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unef

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

2 wire hook

Answers.

What quantity is this sold in?

1EA

What class is the thread series?

Unef

What is the thread quantity per inch?

32

What is the NSN for M39019-2-12?

5925-00-493-1562

How is this classified for shipping?

Schedule B number: 8536200040
Automatic circuit breakers, for a voltage not exceeding 1,000 v

What's the federal classification of M39019-2-12?

FSC 5925 ⁓ Circuit breakers

Excluding relays.

NSN 5925-00-493-1562 CIRCUIT BREAKER

unef thread series 32 thread quantity per inch

NIIN
004931562
NIIN Date
02/18/70
Schedule B
8536200040 
Name Code
00136
FIIG
A030A0
QUP
Historical Price
$35.05 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. MILC39019 Cage 81349
2. 352250008455 Cage H0203

Major End Users Countries and entities

  • - Spain 
  • - Singapore 
  • - Australia 
  • - Canada 
  • - Greece 
  • - Turkey 

Availability for M39019-2-12 A member of our team will provide you with a price and availability quote

Request a Quote »

Similar by Design Other circuit breakers with similar characteristics

Nothing similar to this part number was found in our inventory

M39019-2-12 / Circuit breakerWhat is the formal definition of this item?

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.