Serving our customers with quality and safety first.
4.636in. and 4.700in. ⁓4-45/64"
1.168in. and 1.232in.
1.968in. and 2.032in.
plastic
single pole, double throw
moderately rugged
1
magnetic blowout
2 clip
general purpose warehouse
5.0 amperes ac single location
250.0 ac single location
1000.0 ac single location
overcurrent single location
MAGNETIC-Hydraulic single location
time delay single location
125.0 single location
manual
trip free
1 toggle
TRIP-Reset
at pole one
1 alarm
series trip single location
internal at pole one
0.150 at 200 pct single location and 1.500 at 200 pct single location
fungus resistant
tab, solder lug
10.0 ac
250.0 ac
60.0 single location
2.500 ounces
2 tab, solder lug
1EA
1.968 inches minimum and 2.032 inches maximum
Schedule B number: 8536200040
nmfc 061300
Automatic circuit breakers, for a voltage not exceeding 1,000 v
FSC 5925 ⁓ Circuit breakers
Excluding relays.
1.968" overall width 4.636" overall length
1. | JL1A2-5-3 | Cage 74193 |
Nothing similar to this part number was found in our inventory
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.