Serving our customers with quality and safety first.
MULTIPOLE-Multiple actuator type
5.844in.
3.096in.
plastic
3.546in.
1.032in.
2.750in.
1.031in.
0.218in.
2.609in.
4
magnetic blowout
8 threaded hole
general purpose warehouse
magnetic
32
90.0 amperes ac all locations
120.0 ac first location
240.0 ac fourth location
240.0 ac second location
240.0 ac third location
5000.0 ac all locations
overcurrent all locations
MAGNETIC-Hydraulic all locations
instantaneous first location
time delay fourth location
time delay second location
time delay third location
125.0 all locations
manual
trip free
4 toggle
TRIP-Reset
at each pole
one, two, three, and four linked
relay trip first location
series trip fourth location
series trip second location
series trip third location
0.138in. ⁓9/64"
4.000 at 200 pct fourth location and 10.000 at 200 pct fourth location
4.000 at 200 pct second location and 10.000 at 200 pct second location
4.000 at 200 pct third location and 10.000 at 200 pct third location
shock resistant and vibration resistant
400.0 fourth location
400.0 second location
400.0 third location
440.0 first location
49956-G166010 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
unc
10 threaded stud
1EA
Unc
32
Schedule B number: 8536200040
nmfc 061300
Automatic circuit breakers, for a voltage not exceeding 1,000 v
FSC 5925 ⁓ Circuit breakers
Excluding relays.
unc thread series 32 thread quantity per inch
1. | CD4-Z296-1W | Cage L3330 |
2. | CD4-Z296-1W | Cage 3AQ68 |
3. | CD4-Z296-1W | Cage 74193 |
4. | CD4-Z160-2 | Cage 74193 |
Nothing similar to this part number was found in our inventory
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.