CP53B1EF105K1

CP53B1EF105K1 Circuit Breaker

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. CP53B1EF105K1 specification


The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

Bushing Length
A measurement of the longest dimension of a bushing,in distinction from width.

0.359in.

Body Length
A measurement of the longest dimension of the body,in distinction from width.

0.780in.

Body Width
A measurement taken at right angles to the length of the body,in distinction from thickness.

0.580in.

Case Material
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.

metal

Center To Center Distance Between Terminals Parallel To Length
The center to center distance between terminals parallel to the length of the item.

0.593in.

Switch Contact Arrangement
A designation that describes the basic electrical configuration of a switch.

single pole, single throw, normally closed

Mounting Surface To Terminal End Distance

1.420in.

Pole Quantity
The number of poles included in the item.

1

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

1 threaded bushing

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

32

Maximum Continuous Load Current Rating Per Pole
The maximum current load that each pole is rated to carry continuously.

500.0 milliamperes ac single location and 500.0 milliamperes dc single location

Operating Voltage Type And Rating Per Pole In Volts
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.

115.0 ac single location and 28.0 dc single location

Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.

100.0 ac single location and 100.0 dc single location

Circuit Protection Type
Indicates the type of electrical condition that will cause the device to trip.

overcurrent single location

Trip Release Method
The means by which the trip mechanism is released.

thermal single location

Trip Release Characteristic
Denotes the type of trip release action.

time delay single location

Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.

145.0 single location

Reset Method
The means provided to reposition the mechanism so that the device is ready to function.

manual

Main Contact Tripping Mechanism Type
Indicates the type of mechanism provided for tripping main contacts.

trip free

Manual Actuator Type And Quantity
Indicates the type and number of actuators provided for manual control.

1 PUSH-Pull

Actuator Function
Denotes the action imparted by actuator operation.

TRIP-Reset

Actuator Position Designation
An indication of the designated position of the actuator.

at pole one

Auxiliary Switch Function And Quantity
The function for which the auxiliary switch is designed and the number provided.

1 control

Internal Trip Release Configuration
The basic internal electrical configuration of the trip mechanism.

series trip single location

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.438in. ⁓29/64"

Switch Location And Position Designation
Indicates the location of the switch in relation to its designated position.

external at pole one

Trip Delay Time In Seconds Per Rated Continuous Current
The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.

2.000 at 200 pct single location and 20.000 at 200 pct single location

Inclosure Protection Type For Which Designed
Indicates the type of protection for which the inclosure is designed.

moisture resistant and explosion resistant

Trip Release Ambient Temp Rating
The temperature of the medium surrounding the trip release at which it can be operated continuously.

25.0 deg celsius single location

Switch Terminal Type
Indicates the type of terminal for providing electrical connection to the switch.

tab, solder lug

Switch Current Rating And Type In Amps
The amount of current,expressed in amperes,and the type for which the switch is rated.

0.5 ac and 0.5 dc

Switch Voltage Rating And Type In Volts
The voltage,expressed in volts,and current type for which the switch is rated.

115.0 ac and 28.0 dc

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

400.0 single location

Test Data Document
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.

81349-MIL-C-5809 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

un

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

2 screw

Specification/standard Data
The document designator of the specification or standard which established the item of supply.

96906-MS26574 government standard

Answers.

What quantity is this sold in?

1EA

What class is the thread series?

Un

What is the thread quantity per inch?

32

What is the NSN for CP53B1EF105K1?

5925-00-121-9847

How is this classified for shipping?

Schedule B number: 8536200040
nmfc 061300
Automatic circuit breakers, for a voltage not exceeding 1,000 v

What's the federal classification of CP53B1EF105K1?

FSC 5925 ⁓ Circuit breakers

Excluding relays.

NSN 5925-00-121-9847 CIRCUIT BREAKER

un thread series 32 thread quantity per inch

NIIN
001219847
NIIN Date
11/04/68
Schedule B
8536200040 
Name Code
00136
FIIG
A030A0
Item Weight
0.000lbs
Item Dimensions
40 X 40 X 10
QUP
Historical Price
$128.98 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. AS26574 Cage 81343
2. AS58091 Cage 81343
3. Q531487051 Cage S3092
4. 10503365 Cage 56161
5. 7274-4-1/2 Cage 82647
6. 84402811 Cage C1357
7. 84 303 308 SP 4307-11 Cage C1357
8. 972.55.18.510 Cage S4080
9. MS26574-1/2A Cage 81343
10. MIL-C-5809 Cage 81349
11. MS26574-1/2A Cage 96906

Major End Users Countries and entities

  • - National Aeronautics And Space Administration 
  • - Department of The Navy 
  • - Department of The Army 
  • - U.s. Marine Corps 
  • - Department of The Air Force 
  • - Poland 
  • - Brazil 
  • - Spain 
  • - Singapore 
  • - Australia 
  • - Canada 
  • - New Zealand 
  • - Germany 
  • - Republic of Korea 
  • - Netherlands 
  • - Italy 
  • - Greece 
  • - Turkey 

Availability for CP53B1EF105K1 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other circuit breakers with similar characteristics

Nothing similar to this part number was found in our inventory

CP53B1EF105K1 / Circuit breakerWhat is the formal definition of this item?

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.