Serving our customers with quality and safety first.
single pole type
0.250in.
0.750in.
0.624in.
0.694in. and 0.714in.
boeing B757 aircraft
1.302in. and 1.322in.
1
1 threaded bushing
32
7.500 amperes ac single location and 7.500 amperes dc single location
120.0 ac single location and 30.0 dc single location
2800.0 ac single location and 3400.0 dc single location
overcurrent single location
thermal single location
time delay single location
138.0 single location
manual
trip free
1 PUSH-Pull
0.4688in. ⁓15/32"
4.000 at 200 pct single location and 20.000 at 200 pct single location and 0.400 at 500 pct single location and 2.000 at 500 pct single location and 0.100 at 1000 pct single location and 0.530 at 1000 pct single location
25.0 deg celsius single location
mounting bushing thread class 2a; operating altitude 0.0 to 70000.0 feet; operating force PULL-Out 1.5 to 5.0 pounds and reset force 1.0 to 5.0 pounds
400.0 single location
30.000 grams
uns
2 tab w/screw
Uns
32
Schedule B number: 8536200040
Automatic circuit breakers, for a voltage not exceeding 1,000 v
FSC 5925 ⁓ Circuit breakers
Excluding relays.
Used on boeing b757 aircraft. uns thread series mounting bushing thread class 2a; operating altitude 0.0 to 70000.0 feet; operating force pull-out 1.5 to 5.0 pounds 32 thread quantity per inch
1. | 2TC47-71/2 | Cage 82647 |
2. | 2TC47-7-5 | Cage 82647 |
Nothing similar to this part number was found in our inventory
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.