APL2-9433-1

APL294331 Circuit Breaker

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. APL2-9433-1 specification

Pole Quantity
The number of poles included in the item.

1

Maximum Continuous Load Current Rating Per Pole
The maximum current load that each pole is rated to carry continuously.

20.0 amperes dc single location

Operating Voltage Type And Rating Per Pole In Volts
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.

50.0 dc single location

Trip Release Method
The means by which the trip mechanism is released.

magnetic single location

Trip Release Characteristic
Denotes the type of trip release action.

time delay single location

Main Contact Tripping Mechanism Type
Indicates the type of mechanism provided for tripping main contacts.

trip free

Trip Delay Time In Seconds Per Rated Continuous Current
The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.

0.500 at 125 pct single location and 6.500 at 125 pct single location and 0.300 at 150 pct single location and 3.000 at 150 pct single location and 0.130 at 200 pct single location and 1.200 at 200 pct single location and 0.031 at 400 pct single location and 0.220 at 400 pct single location and 0.031 at 600 pct single location and 0.220 at 600 pct single location and 0.0110 at 800 pct single location and 0.110 at 800 pct single location and 0.004 at 1000 pct single location and 0.050 at 1000 pct single location

Answers.

What is the NSN for APL2-9433-1?

5925-01-255-3079

How is this classified for shipping?

Schedule B number: 8536200040
Automatic circuit breakers, for a voltage not exceeding 1,000 v

What's the federal classification of APL2-9433-1?

FSC 5925 ⁓ Circuit breakers

Excluding relays.

NSN 5925-01-255-3079 CIRCUIT BREAKER

NIIN
012553079
NIIN Date
05/18/87
Schedule B
8536200040 
Name Code
00136
FIIG
A030A0
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 911383-001 Cage 19156

Major End Users Countries and entities

  • - United Kingdom 

Availability for APL2-9433-1 A member of our team will provide you with a price and availability quote

Request a Quote »

Similar by Design Other circuit breakers with similar characteristics

Nothing similar to this part number was found in our inventory

APL2-9433-1 / Circuit breakerWhat is the formal definition of this item?

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.