APGN266-1REC4-28055-1

APGN2661REC4280551 Circuit Breaker

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. APGN266-1REC4-28055-1 specification

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

MULTIPOLE-Single actuator type

Bushing Length
A measurement of the longest dimension of a bushing,in distinction from width.

0.625in.

Body Length
A measurement of the longest dimension of the body,in distinction from width.

2.000in.

Body Width
A measurement taken at right angles to the length of the body,in distinction from thickness.

2.265in.

Case Material
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.

metal

Center To Center Distance Between Terminals Parallel To Length
The center to center distance between terminals parallel to the length of the item.

1.530in.

Center To Center Distance Between Terminals Parallel To Width
The center to center distance between terminals parallel to the width of the item.

0.750in.

Switch Contact Arrangement
A designation that describes the basic electrical configuration of a switch.

double pole, single throw, normally open

End Item Identification
The national stock number or the identification information of the end equipment for which the item is a part.

F15I lantirn

Mounting Surface To Terminal End Distance

2.232in.

Pole Quantity
The number of poles included in the item.

3

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

threaded bushing w/panel seal

Maximum Continuous Load Current Rating Per Pole
The maximum current load that each pole is rated to carry continuously.

30.0 amperes ac all locations

Operating Voltage Type And Rating Per Pole In Volts
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.

115.0 ac all locations

Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.

2000.0 ac all locations

Circuit Protection Type
Indicates the type of electrical condition that will cause the device to trip.

overcurrent all locations

Trip Release Method
The means by which the trip mechanism is released.

magnetic all locations

Auxiliary Trip Coil Voltage Type And Rating In Volts
Indicates the type and voltage rating required to operate the auxiliary /remotely actuated/ trip actuator,expressed in volts.

10.0 ac third location

Trip Release Characteristic
Denotes the type of trip release action.

time delay all locations

Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.

150.0 all locations

Ultimate Trip Time Per Pole In Seconds
The ultimate time per pole in which the device must trip,expressed in seconds.

0.500 all locations

Reset Method
The means provided to reposition the mechanism so that the device is ready to function.

manual

Main Contact Tripping Mechanism Type
Indicates the type of mechanism provided for tripping main contacts.

trip free

Manual Actuator Type And Quantity
Indicates the type and number of actuators provided for manual control.

1 toggle

Actuator Function
Denotes the action imparted by actuator operation.

TRIP-Reset

Actuator Position Designation
An indication of the designated position of the actuator.

at pole two

Auxiliary Switch Function And Quantity
The function for which the auxiliary switch is designed and the number provided.

alarm

Internal Trip Release Configuration
The basic internal electrical configuration of the trip mechanism.

series trip w/auxiliary load terminal third location

Internal Trip Release Configuration
The basic internal electrical configuration of the trip mechanism.

series trip second location

Internal Trip Release Configuration
The basic internal electrical configuration of the trip mechanism.

series trip w/dual rating first location

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

32.000in. ⁓32-1/64"

Trip Release Duty Cycle
The working period which the trip release is designed to operate.

continuous all locations

Switch Location And Position Designation
Indicates the location of the switch in relation to its designated position.

internal at pole three

Trip Delay Time In Seconds Per Rated Continuous Current
The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.

0.500 at 150 pct all locations

Trip Release Ambient Temp Rating
The temperature of the medium surrounding the trip release at which it can be operated continuously.

-40.0 deg celsius all locations and 85.0 deg celsius all locations

Thread Tolerance Class
A numeric-alpha designator indicating established pitch and crest diameter tolerance position and grade.

2b external

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

400.0 all locations

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unef

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

quick disconnect, male

Answers.

What quantity is this sold in?

1EA

What class is the thread series?

Unef

What is the NSN for APGN266-1REC4-28055-1?

5925-01-441-9569

How is this classified for shipping?

Schedule B number: 8536200040
nmfc 061300
Automatic circuit breakers, for a voltage not exceeding 1,000 v

What's the federal classification of APGN266-1REC4-28055-1?

FSC 5925 ⁓ Circuit breakers

Excluding relays.

NSN 5925-01-441-9569 CIRCUIT BREAKER

Used on f15i lantirn. unef thread series

NIIN
014419569
NIIN Date
02/27/97
Schedule B
8536200040 
Name Code
00136
FIIG
A030A0
Item Weight
0.000lbs
Item Dimensions
--
QUP
Historical Price
$547.68 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

Major End Users Countries and entities

  • - Department of The Air Force 
  • - Greece 

Availability for APGN266-1REC4-28055-1 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other circuit breakers with similar characteristics

Nothing similar to this part number was found in our inventory

APGN266-1REC4-28055-1 / Circuit breakerWhat is the formal definition of this item?

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.