Serving our customers with quality and safety first.
+0.4752/+0.4787in.
MULTIPOLE-Single actuator type
0.625in.
2.000in.
2.250in.
plastic
1.530in.
0.750in.
at 12 oclock and at 3 oclock and at 9 oclock
0.656in.
0.130in.
0.151in. and 0.161in.
moderately rugged
2.232in.
3
magnetic blowout
1 threaded bushing w/panel seal
general purpose warehouse
magnetic
32
2.5 amperes ac all locations
250.0 ac all locations
3500.0 ac all locations
overcurrent all locations
MAGNETIC-Hydraulic all locations
time delay all locations
115.0 all locations
manual
trip free
1 toggle
TRIP-Reset
at pole two
series trip all locations
0.500in. ⁓1/2"
10.000 at 200 pct all locations and 150.000 at 200 pct all locations
hermetically sealed and shock resistant and vibration resistant
50.0 single location or 60.0 single location
9.000 ounces
un
6 tab w/screw
Un
32
Schedule B number: 8536200040
Automatic circuit breakers, for a voltage not exceeding 1,000 v
FSC 5925 ⁓ Circuit breakers
Excluding relays.
un thread series 32 thread quantity per inch
Nothing similar to this part number was found in our inventory
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.