Datasheet. AP7-1-50-153 specification

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

single pole type

Mounting Slot Width
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.

0.130in.

Bushing Length
A measurement of the longest dimension of a bushing,in distinction from width.

0.380in.

Body Length
A measurement of the longest dimension of the body,in distinction from width.

1.562in.

Body Width
A measurement taken at right angles to the length of the body,in distinction from thickness.

1.281in.

Case Material
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.

metal

Center To Center Distance Between Terminals Parallel To Length
The center to center distance between terminals parallel to the length of the item.

0.875in.

Mounting Surface To Terminal End Distance

1.605in.

Pole Quantity
The number of poles included in the item.

1

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

2 slot

Maximum Continuous Load Current Rating Per Pole
The maximum current load that each pole is rated to carry continuously.

20.0 amperes dc single location

Operating Voltage Type And Rating Per Pole In Volts
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.

15.0 dc single location

Circuit Protection Type
Indicates the type of electrical condition that will cause the device to trip.

overcurrent single location

Trip Release Method
The means by which the trip mechanism is released.

magnetic single location

Trip Release Characteristic
Denotes the type of trip release action.

time delay single location

Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.

100.0 single location

Reset Method
The means provided to reposition the mechanism so that the device is ready to function.

automatic

Trip Delay Time In Seconds Per Rated Continuous Current
The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.

40.0 at 100 pct and 0.015 at 800 pct single location

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

2 quick disconnect, male

Answers.

What is the NSN for AP7-1-50-153?

5925-01-595-2375

How is this classified for shipping?

Schedule B number: 8536200040
Automatic circuit breakers, for a voltage not exceeding 1,000 v

What's the federal classification of AP7-1-50-153?

FSC 5925 ⁓ Circuit breakers

Excluding relays.

NSN 5925-01-595-2375 CIRCUIT BREAKER

NIIN
015952375
NIIN Date
04/25/11
Schedule B
8536200040 
Name Code
00136
FIIG
A030A0
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Major End Users Countries and entities

  • - France 

Availability for AP7-1-50-153 A member of our team will provide you with a price and availability quote

Request a Quote »

Similar by Design Other circuit breakers with similar characteristics

Nothing similar to this part number was found in our inventory

AP7-1-50-153 / Circuit breakerWhat is the formal definition of this item?

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.