Datasheet. AM2R-D3-LC07D-A-20-2 specification

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

MULTIPOLE-Multiple actuator type

Body Length
A measurement of the longest dimension of the body,in distinction from width.

2.469in. and 2.531in.

Body Width
A measurement taken at right angles to the length of the body,in distinction from thickness.

1.469in. and 1.531in.

Case Material
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.

plastic

Center To Center Distance Between Terminals Parallel To Length
The center to center distance between terminals parallel to the length of the item.

1.909in. and 1.971in.

Center To Center Distance Between Terminals Parallel To Width
The center to center distance between terminals parallel to the width of the item.

0.719in. and 0.781in.

Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
The distance between centerlines of mounting facilities parallel to the length of the item.

2.031in. and 2.093in.

Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
The distance between centerlines of mounting facilities parallel to the width of the item.

0.719in. and 0.781in.

End Item Identification
The national stock number or the identification information of the end equipment for which the item is a part.

missle, minuteman LGM-30, test set

Boss Height

0.109in. and 0.171in.

Mounting Surface To Terminal End Distance

1.829in. and 1.891in.

Pole Quantity
The number of poles included in the item.

2

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

4 threaded hole

Features Provided
Those features,not otherwise specified,which may be required for proper functioning of the item.

high inrush protection

Maximum Continuous Load Current Rating Per Pole
The maximum current load that each pole is rated to carry continuously.

20.0 amperes ac all locations and 20.0 amperes dc all locations

Operating Voltage Type And Rating Per Pole In Volts
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.

240.0 ac all locations and 80.0 dc all locations

Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.

5000.0 ac all locations and 5000.0 dc all locations

Circuit Protection Type
Indicates the type of electrical condition that will cause the device to trip.

overcurrent all locations

Trip Release Method
The means by which the trip mechanism is released.

MAGNETIC-Hydraulic all locations

Trip Release Characteristic
Denotes the type of trip release action.

time delay all locations

Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.

135.0 all locations

Reset Method
The means provided to reposition the mechanism so that the device is ready to function.

manual

Main Contact Tripping Mechanism Type
Indicates the type of mechanism provided for tripping main contacts.

trip free

Manual Actuator Type And Quantity
Indicates the type and number of actuators provided for manual control.

2 toggle

Actuator Function
Denotes the action imparted by actuator operation.

TRIP-Reset

Actuator Position Designation
An indication of the designated position of the actuator.

at each pole

External Actuator Linkage Arrangement
Indicates the arrangement of the externally connected actuators.

one and two linked

Internal Trip Release Configuration
The basic internal electrical configuration of the trip mechanism.

series trip all locations

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.138in. ⁓9/64"

Trip Delay Time In Seconds Per Rated Continuous Current
The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.

1.700 at 200 pct all locations and 18.000 at 200 pct all locations

Part Name Assigned By Controlling Agency
The name assigned to the item by the government agency or commercial organization controlling the design of the item.

circuit breaker

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

temp range M40.0 to 185.0 fah. tested iaw MIL-STD-202 methods 101, 106, 103 cond a, 213 cond i, 204, 301, 302.

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

50.0 all locations or 60.0 all locations

Test Data Document
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.

MIL-C-55629 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) . and MIL-STD-202 standard (includes industry or association standards, individual manufactureer standards, etc.) .

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unc

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

4 threaded stud

Answers.

What class is the thread series?

Unc

What is the NSN for AM2R-D3-LC07D-A-20-2?

5925-01-517-3989

How is this classified for shipping?

Schedule B number: 8536200040
nmfc 061300
Automatic circuit breakers, for a voltage not exceeding 1,000 v

What's the federal classification of AM2R-D3-LC07D-A-20-2?

FSC 5925 ⁓ Circuit breakers

Excluding relays.

NSN 5925-01-517-3989 CIRCUIT BREAKER

Used on missle, minuteman lgm-30, test set. unc thread series temp range M40.0 to 185.0 fah. tested iaw mil-std-202 methods 101, 106, 103 cond a, 213 cond i, 204, 301, 302. circuit breaker

NIIN
015173989
NIIN Date
02/06/04
Schedule B
8536200040 
Name Code
00136
FIIG
A030A0
QUP
 
Historical Price
$368.60 EA
DEMIL / ITAR
USML/ITAR controlled item (Code: B)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. L9668-111-061-01 Cage 96362
2. AM2S-D3-A-20-2 Cage 1W134

Major End Users Countries and entities

  • - Department of The Navy 
  • - Department of The Air Force 

Availability for AM2R-D3-LC07D-A-20-2 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other circuit breakers with similar characteristics

Nothing similar to this part number was found in our inventory

AM2R-D3-LC07D-A-20-2 / Circuit breakerWhat is the formal definition of this item?

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.