Serving our customers with quality and safety first.
single pole type
0.250in.
0.780in.
0.539in.
plastic
0.593in.
single pole, double throw
moderately rugged
1.525in.
1
1 threaded bushing w/panel seal
general purpose warehouse
32
7.5 amperes ac single location and 7.5 amperes dc single location
120.0 ac single location and 28.0 dc single location
5000.0 ac single location and 2500.0 dc single location
overcurrent single location
thermal single location
time delay single location
150.0 single location
manual
trip free
1 PUSH-Pull
TRIP-Reset
at pole one
1 alarm
series trip single location
0.438in. ⁓29/64"
internal at pole one
2.000 at 200 pct single location and 20.000 at 200 pct single location
corrosion resistant and dustproof and explosion resistant and fungus resistant and moisture resistant and sand resistant and vibration resistant
25.0 deg celsius single location
tab, solder lug
3.0 ac and 5.0 dc
120.0 ac and 30.0 dc
400.0 single location
0.066 pounds
96906-MS26574 standard (includes industry or association standards, individual manufactureer standards, etc.) .
un
2 tab w/screw
81349-MIL-C-5809 government specification
1EA
Un
32
Schedule B number: 8536200040
nmfc 061300
Automatic circuit breakers, for a voltage not exceeding 1,000 v
FSC 5925 ⁓ Circuit breakers
Excluding relays.
un thread series 32 thread quantity per inch
1. | MS26574-7-1-2 | Cage 96906 |
2. | MS26574-7-1/2A | Cage 96906 |
3. | AS58091 | Cage 81349 |
4. | 419073-9 | Cage 96214 |
5. | Q531487059 | Cage S3092 |
6. | 6415841 | Cage 001JK |
7. | MS26574-7-1/2A | Cage FB011 |
8. | 6415841 | Cage FB459 |
9. | MIL-C-5809 | Cage 81349 |
10. | 6415841 | Cage S4956 |
11. | MS26574-7-1/2A | Cage 96906 |
12. | AS58091 | Cage 81349 |
13. | MS26574-7-1-2 | Cage 96906 |
14. | 419073-9 | Cage 96214 |
15. | Q531487059 | Cage S3092 |
16. | 6415841 | Cage 001JK |
17. | MS26574-7-1/2A | Cage FB011 |
18. | 6415841 | Cage FB459 |
19. | MIL-C-5809 | Cage 81349 |
20. | 6415841 | Cage S4956 |
Nothing similar to this part number was found in our inventory
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.