single pole type
3.250in. ⁓3-1/4"
1.200in.
metal
1.530in.
0.172in.
2.940in.
4.260in.
1
2 unthreaded hole
5.0 amperes dc single location
28.0 dc single location and 115.0 ac single location
3600.0 ac single location
overcurrent single location
thermal single location
time delay single location
200.0 single location
automatic
series trip single location
7.000 at 200 pct single location and 40.000 at 200 pct single location and 1.200 at 400 pct single location and 6.400 at 400 pct single location and 0.300 at 1000 pct single location and 1.200 at 1000 pct single location
-54.0 deg celsius single location and 71.0 deg celsius single location
400.0 single location
81349-MIL-C-83383 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) . and 81349--83383/02 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
2 threaded stud
81349-MIL-C-83383 government specification and 81349--83383/02 government specification
1EA
Schedule B number: 8536200040
nmfc 061300
Automatic circuit breakers, for a voltage not exceeding 1,000 v
FSC 5925 ⁓ Circuit breakers
Excluding relays.
3.250" overall length
1. | M83383/02-01 | Cage 81349 |
2. | MIL-PRF-83383/2 | Cage 81349 |
3. | MIL-C-83383 | Cage 81349 |
Nothing similar to this part number was found in our inventory
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.