6510-002-10

651000210 Circuit Breaker

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 6510-002-10 specification

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

rectangular dimensional envelope

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

4.260in. ⁓4-17/64"

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

1.200in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

3.250in.

Case Material
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.

plastic

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.172in.

Switch Contact Arrangement
A designation that describes the basic electrical configuration of a switch.

single pole, double throw

End Item Identification
The national stock number or the identification information of the end equipment for which the item is a part.

1520-01-125-5476

Pole Quantity
The number of poles included in the item.

1

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

2 unthreaded hole

Maximum Continuous Load Current Rating Per Pole
The maximum current load that each pole is rated to carry continuously.

10.0 amperes ac single location and 10.0 amperes dc single location

Operating Voltage Type And Rating Per Pole In Volts
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.

115.0 ac single location and 28.0 dc single location

Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.

3600.0 ac single location and 3600.0 dc single location

Circuit Protection Type
Indicates the type of electrical condition that will cause the device to trip.

overcurrent single location

Trip Release Method
The means by which the trip mechanism is released.

thermal single location

Trip Release Characteristic
Denotes the type of trip release action.

time delay single location

Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.

150.0 single location

Reset Method
The means provided to reposition the mechanism so that the device is ready to function.

automatic

Main Contact Tripping Mechanism Type
Indicates the type of mechanism provided for tripping main contacts.

trip free

Auxiliary Switch Function And Quantity
The function for which the auxiliary switch is designed and the number provided.

1 alarm

Internal Trip Release Configuration
The basic internal electrical configuration of the trip mechanism.

series trip single location

Switch Location And Position Designation
Indicates the location of the switch in relation to its designated position.

internal at pole one

Trip Delay Time In Seconds Per Rated Continuous Current
The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.

12.000 at 200 pct single location and 42.000 at 200 pct single location

Inclosure Protection Type For Which Designed
Indicates the type of protection for which the inclosure is designed.

fungus proof

Trip Release Ambient Temp Rating
The temperature of the medium surrounding the trip release at which it can be operated continuously.

-54.0 deg celsius single location and 71.0 deg celsius single location

Switch Terminal Type
Indicates the type of terminal for providing electrical connection to the switch.

quick disconnect, female

Switch Current Rating And Type In Amps
The amount of current,expressed in amperes,and the type for which the switch is rated.

5.0 ac and 5.0 dc

Switch Voltage Rating And Type In Volts
The voltage,expressed in volts,and current type for which the switch is rated.

115.0 ac and 28.0 dc

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

400.0 single location

Test Data Document
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.

81349-MIL-C-83383 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

2 threaded stud

Specification/standard Data
The document designator of the specification or standard which established the item of supply.

81349-MIL-C-83383/2 government specification

Answers.

What quantity is this sold in?

1EA

What is the overall width?

3.250 inches maximum

What is the NSN for 6510-002-10?

5925-01-197-4686

How is this classified for shipping?

Schedule B number: 8536200040
nmfc 061300
Automatic circuit breakers, for a voltage not exceeding 1,000 v

What's the federal classification of 6510-002-10?

FSC 5925 ⁓ Circuit breakers

Excluding relays.

NSN 5925-01-197-4686 CIRCUIT BREAKER

Used on 1520-01-125-5476. 3.250" overall width 4.260" overall length

NIIN
011974686
NIIN Date
12/21/84
Schedule B
8536200040 
Name Code
00136
FIIG
A030A0
Item Weight
0.100lbs
Item Dimensions
50 X 50 X 20
QUP
Historical Price
$2,984.43 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. M83383/02-03 Cage 81349
2. MIL-C-83383/2 Cage 81349

Major End Users Countries and entities

  • - Department of The Navy 
  • - Department of The Army 
  • - Department of The Air Force 

Availability for 6510-002-10 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other circuit breakers with similar characteristics

Nothing similar to this part number was found in our inventory

6510-002-10 / Circuit breakerWhat is the formal definition of this item?

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.