Serving our customers with quality and safety first.
single pole type
0.250in.
0.781in.
0.593in.
plastic
0.500in.
moderately rugged
mrap RG-33
1.343in.
1
1 threaded bushing
general purpose warehouse
32
20.0 amperes ac single location and 20.0 amperes dc single location
115.0 ac single location and 28.0 dc single location
2000.0 ac single location and 2500.0 dc single location
overcurrent single location
thermal single location
time delay single location
138.0 single location
manual
trip free
1 PUSH-Pull
TRIP-Reset
at pole one
series trip single location
0.4375in. ⁓29/64"
1.500 at 200 pct single location and 40.000 at 200 pct single location
vibration resistant
25.0 deg celsius single location
400.0 single location
0.055 pounds
81349-MIL-C-5809 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
un
2 tab w/screw
96906-MS3320 government standard
On 09/21/2015 under contract SPE7M115M8840 for qty 115
1EA
Un
32
Schedule B number: 8710000090
nmfc 061300
Parts of armored fighting vehicles,motorized, whether or not fitted with weapons
FSC 5925 ⁓ Circuit breakers
Excluding relays.
Used on mrap rg-33. un thread series 32 thread quantity per inch
1. | AS33201-20V | Cage 81343 |
2. | AS58091 | Cage 81343 |
3. | MS3320-20V | Cage 14304 |
4. | MS3320-20V | Cage 81343 |
5. | MIL-C-5809 | Cage 81349 |
6. | MS3320-20 | Cage 96906 |
7. | MS3320-20V | Cage 96906 |
8. | 10135264 | Cage A486G |
9. | 4310-001-20 | Cage 8H694 |
Nothing similar to this part number was found in our inventory
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.