single pole type
0.359in.
0.780in.
0.580in.
metal
0.593in.
moderately rugged
1.420in.
1
1 threaded bushing w/panel seal
general purpose warehouse
32
5.0 amperes ac single location and 5.0 amperes dc single location
200.0 ac single location and 28.0 dc single location
800.0 ac single location and 800.0 dc single location
overcurrent single location
thermal single location
time delay single location
145.0 single location
manual
trip free
1 PUSH-Pull
TRIP-Reset
at pole one
series trip single location
0.438in. ⁓29/64"
2.000 at 200 pct single location and 20.000 at 200 pct single location
explosion resistant and moisture resistant
25.0 deg celsius single location
400.0 single location
81349-MIL-C-5809 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
un
2 tab w/screw
96906-MS26574 government standard
On 05/01/2013 under contract SPM7M113D5N550002 for qty 508
1EA
Un
32
Schedule B number: 8536200040
nmfc 061300
Automatic circuit breakers, for a voltage not exceeding 1,000 v
FSC 5925 ⁓ Circuit breakers
Excluding relays.
un thread series 32 thread quantity per inch
1. | GC885FD5 | Cage 26512 |
2. | D7274-2-5 | Cage 82647 |
3. | AS26574 | Cage 81343 |
4. | AS58091 | Cage 81343 |
5. | 11040390-3 | Cage 18876 |
6. | 3600140-3 | Cage 07421 |
7. | 7274-2-5 | Cage 82647 |
8. | 7274-25-5 | Cage 82647 |
9. | 7274-26-5 | Cage 82647 |
10. | 7277-2-5 | Cage 82647 |
11. | 972.55.18.517 | Cage S4080 |
12. | 235986 | Cage H0212 |
13. | MS26574-5 | Cage 81343 |
14. | MIL-C-5809 | Cage 81349 |
15. | MS26574-5 | Cage 96906 |
16. | 7277-2-5 | Cage FA9C1 |
17. | 7S235986 | Cage H0212 |
Nothing similar to this part number was found in our inventory
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.