Datasheet. 403D072SUB4SH1T03 specification

Case Material
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.

metal

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.562in.

Pole Quantity
The number of poles included in the item.

2

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

8 unthreaded hole

Maximum Continuous Load Current Rating Per Pole
The maximum current load that each pole is rated to carry continuously.

2600.0 amperes dc all locations

Operating Voltage Type And Rating Per Pole In Volts
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.

250.0 dc all locations

Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.

100000.0 dc all locations

Circuit Protection Type
Indicates the type of electrical condition that will cause the device to trip.

overcurrent all locations

Trip Release Method
The means by which the trip mechanism is released.

magnetic all locations

Trip Release Characteristic
Denotes the type of trip release action.

instantaneous all locations and time delay all locations

Reset Method
The means provided to reposition the mechanism so that the device is ready to function.

automatic

Manual Actuator Type And Quantity
Indicates the type and number of actuators provided for manual control.

1 rotary

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

4 bus bar

Reference Number Differentiating Characteristics
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.

differentiated by pac cprg

Answers.

What is the NSN for 403D072SUB4SH1T03?

5925-00-812-0625

How is this classified for shipping?

Schedule B number: 8536200040
nmfc 061300
Automatic circuit breakers, for a voltage not exceeding 1,000 v

What's the federal classification of 403D072SUB4SH1T03?

FSC 5925 ⁓ Circuit breakers

Excluding relays.

NSN 5925-00-812-0625 CIRCUIT BREAKER

NIIN
008120625
NIIN Date
01/01/63
Schedule B
8536200040 
Name Code
00136
FIIG
A030A0
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
--
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 403D072SH2 Cage 11660
2. S035Y3052 Cage 11660
3. S035Y5883 Cage 11660
4. S035Y6313 Cage 11660
5. S035Y6487 Cage 11660
6. S035Y7265 Cage 11660
7. S035Y8240 Cage 11660
8. S035Y8861 Cage 11660
9. S035Y9519 Cage 11660
10. S035Y9626 Cage 11660
11. S043Y2523 Cage 11660
12. S043Y2639 Cage 11660
13. S043Y5700 Cage 11660

Availability for 403D072SUB4SH1T03 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
77.5
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other circuit breakers with similar characteristics

Nothing similar to this part number was found in our inventory

403D072SUB4SH1T03 / Circuit breakerWhat is the formal definition of this item?

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.