205-1-1REC2-65-4-202AMO

20511REC2654202AMO Circuit Breaker

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 205-1-1REC2-65-4-202AMO specification

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

single pole type

Body Length
A measurement of the longest dimension of the body,in distinction from width.

2.490in.

Body Width
A measurement taken at right angles to the length of the body,in distinction from thickness.

0.750in.

Case Material
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.

plastic

Center To Center Distance Between Terminals Parallel To Length
The center to center distance between terminals parallel to the length of the item.

1.940in.

Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
The distance between centerlines of mounting facilities parallel to the length of the item.

2.060in.

Switch Contact Arrangement
A designation that describes the basic electrical configuration of a switch.

single pole, double throw

Boss Height

0.150in.

Mounting Surface To Terminal End Distance

2.755in.

Pole Quantity
The number of poles included in the item.

1

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

2 threaded hole

Features Provided
Those features,not otherwise specified,which may be required for proper functioning of the item.

high inrush protection

Maximum Continuous Load Current Rating Per Pole
The maximum current load that each pole is rated to carry continuously.

2.0 amperes ac single location

Operating Voltage Type And Rating Per Pole In Volts
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.

250.0 ac single location

Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.

1000.0 ac single location

Circuit Protection Type
Indicates the type of electrical condition that will cause the device to trip.

overcurrent single location

Trip Release Method
The means by which the trip mechanism is released.

MAGNETIC-Hydraulic single location

Trip Release Characteristic
Denotes the type of trip release action.

time delay single location

Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.

125.0 single location

Ultimate Trip Time Per Pole In Seconds
The ultimate time per pole in which the device must trip,expressed in seconds.

8.000 single location and 60.000 single location

Reset Method
The means provided to reposition the mechanism so that the device is ready to function.

manual

Main Contact Tripping Mechanism Type
Indicates the type of mechanism provided for tripping main contacts.

trip free

Manual Actuator Type And Quantity
Indicates the type and number of actuators provided for manual control.

1 toggle

Actuator Function
Denotes the action imparted by actuator operation.

TRIP-Reset

Actuator Position Designation
An indication of the designated position of the actuator.

at pole one

Auxiliary Switch Function And Quantity
The function for which the auxiliary switch is designed and the number provided.

1 control

Internal Trip Release Configuration
The basic internal electrical configuration of the trip mechanism.

series trip single location

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

3.0 mm

Trip Release Duty Cycle
The working period which the trip release is designed to operate.

continuous single location

Thread Pitch In Millimeters
A measurement of distance between corresponding points on two adjacent threads measured parallel to the thread axis,expressed in millimeters.

0.50

Switch Location And Position Designation
Indicates the location of the switch in relation to its designated position.

internal at pole one

Trip Delay Time In Seconds Per Rated Continuous Current
The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.

8.000 at 125 pct single location and 60.000 at 125 pct single location

Inclosure Protection Type For Which Designed
Indicates the type of protection for which the inclosure is designed.

dustproof

Switch Terminal Type
Indicates the type of terminal for providing electrical connection to the switch.

quick disconnect, male

Switch Current Rating And Type In Amps
The amount of current,expressed in amperes,and the type for which the switch is rated.

10.0 ac

Switch Voltage Rating And Type In Volts
The voltage,expressed in volts,and current type for which the switch is rated.

250.0 ac

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

50.0 single location or 60.0 single location

Test Data Document
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.

81541-2002 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

iso s

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

2 threaded stud

Answers.

What class is the thread series?

Iso s

What is the NSN for 205-1-1REC2-65-4-202AMO?

5925-01-178-7542

How is this classified for shipping?

Schedule B number: 8536200040
Automatic circuit breakers, for a voltage not exceeding 1,000 v

What's the federal classification of 205-1-1REC2-65-4-202AMO?

FSC 5925 ⁓ Circuit breakers

Excluding relays.

NSN 5925-01-178-7542 CIRCUIT BREAKER

iso s thread series

NIIN
011787542
NIIN Date
05/10/84
Schedule B
8536200040 
Name Code
00136
FIIG
A030A0
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 91500994 Cage F6481

Major End Users Countries and entities

  • - France 

Availability for 205-1-1REC2-65-4-202AMO A member of our team will provide you with a price and availability quote

Request a Quote »

Similar by Design Other circuit breakers with similar characteristics

Nothing similar to this part number was found in our inventory

205-1-1REC2-65-4-202AMO / Circuit breakerWhat is the formal definition of this item?

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.