203-2-2-41-252-4-1-1A

2032241252411A Circuit Breaker

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 203-2-2-41-252-4-1-1A specification

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

single pole type

Body Length
A measurement of the longest dimension of the body,in distinction from width.

2.000in.

Body Width
A measurement taken at right angles to the length of the body,in distinction from thickness.

0.920in.

Body Height
A measurement from the bottom to the top of the body,in distinction from depth.

1.770in.

Case Material
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.

plastic

Switch Contact Arrangement
A designation that describes the basic electrical configuration of a switch.

single pole, double throw

Boss Height

0.125in.

Pole Quantity
The number of poles included in the item.

1

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

2 clip

Maximum Continuous Load Current Rating Per Pole
The maximum current load that each pole is rated to carry continuously.

2.5 amperes ac single location

Operating Voltage Type And Rating Per Pole In Volts
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.

250.0 ac single location

Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.

1000.0 ac single location

Circuit Protection Type
Indicates the type of electrical condition that will cause the device to trip.

overcurrent single location

Trip Release Method
The means by which the trip mechanism is released.

MAGNETIC-Hydraulic single location

Trip Release Characteristic
Denotes the type of trip release action.

time delay single location

Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.

125.0 single location

Ultimate Trip Time Per Pole In Seconds
The ultimate time per pole in which the device must trip,expressed in seconds.

0.200 single location and 7.000 single location

Reset Method
The means provided to reposition the mechanism so that the device is ready to function.

manual

Main Contact Tripping Mechanism Type
Indicates the type of mechanism provided for tripping main contacts.

trip free

Manual Actuator Type And Quantity
Indicates the type and number of actuators provided for manual control.

1 toggle

Actuator Function
Denotes the action imparted by actuator operation.

TRIP-Reset

Actuator Position Designation
An indication of the designated position of the actuator.

at pole one

Auxiliary Switch Function And Quantity
The function for which the auxiliary switch is designed and the number provided.

1 alarm

Internal Trip Release Configuration
The basic internal electrical configuration of the trip mechanism.

series trip single location

Switch Location And Position Designation
Indicates the location of the switch in relation to its designated position.

external at pole one

Trip Delay Time In Seconds Per Rated Continuous Current
The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.

0.050 at 200 pct single location and 0.950 at 200 pct single location and 0.020 at 400 pct single location and 0.240 at 400 pct single location and 0.130 at 600 pct single location and 0.060 at 800 pct single location

Switch Terminal Type
Indicates the type of terminal for providing electrical connection to the switch.

turret

Switch Current Rating And Type In Amps
The amount of current,expressed in amperes,and the type for which the switch is rated.

5.0 ac

Switch Voltage Rating And Type In Volts
The voltage,expressed in volts,and current type for which the switch is rated.

250.0 ac

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

flush mtg hardware incl; illuminated handle

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

400.0 single location

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

2 tab, solder lug

Answers.

What is the NSN for 203-2-2-41-252-4-1-1A?

5925-01-165-2919

How is this classified for shipping?

Schedule B number: 8536200040
Automatic circuit breakers, for a voltage not exceeding 1,000 v

What's the federal classification of 203-2-2-41-252-4-1-1A?

FSC 5925 ⁓ Circuit breakers

Excluding relays.

NSN 5925-01-165-2919 CIRCUIT BREAKER

flush mtg hardware incl; illuminated handle

NIIN
011652919
NIIN Date
10/27/83
Schedule B
8536200040 
Name Code
00136
FIIG
A030A0
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Major End Users Countries and entities

  • - Germany 

Availability for 203-2-2-41-252-4-1-1A A member of our team will provide you with a price and availability quote

Request a Quote »

Similar by Design Other circuit breakers with similar characteristics

Nothing similar to this part number was found in our inventory

203-2-2-41-252-4-1-1A / Circuit breakerWhat is the formal definition of this item?

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.