Serving our customers with quality and safety first.
single pole type
0.400in.
1.140in.
0.570in.
plastic
0.780in.
force provider (used on: 4120-01-413-7835)
2.220in.
1
1 threaded bushing
general purpose warehouse
27
5.0 amperes ac single location and 5.0 amperes dc single location
250.0 ac single location and 28.0 dc single location
2000.0 ac single location and 2000.0 dc single location
overcurrent single location
thermal single location
time delay single location
125.0 single location
manual
trip free
1 push button
TRIP-Reset
at pole one
series trip single location
0.375in. ⁓3/8"
10.000 at 200 pct single location and 40.000 at 200 pct single location
dustproof and fungus resistant
40.0 deg celsius single location
this item has a new feature: on/off switch builded within the circuit breaker // specifications: a. max voltage ratings (250 vac & 28 vdc) x b. max interrupting capacity (< 2000 amp) x c. dielectric strength (1500 vac) x d. insulation resistance (100 megohm) x e. life (6000 cycles at rated current) x f. current rating (5 amp) x g. temperature range (-40 deg.f to 160 deg.f)
60.0 single location
uns
2 screw
1EA
Uns
27
Schedule B number: 8536200040
nmfc 061300
Automatic circuit breakers, for a voltage not exceeding 1,000 v
FSC 5925 ⁓ Circuit breakers
Excluding relays.
Used on force provider (: 4120-01-413-7835). uns thread series this item has a new feature: on/off switch builded within the circuit breaker // specifications: a. max voltage ratings (250 vac & 28 vdc) x b. max interrupting capacity (< 2000 amp) x c. dielectric strength (1500 vac) x d. insulation resistance (100 megohm) x e. life (6000 cycles at rated current) x f. current rating (5 amp) x g. temperature range (-40 deg.f to 160 deg.f) 27 thread quantity per inch
1. | 13230E3558 | Cage 97403 |
2. | 45-700-IG1-S10-5A | Cage 06402 |
3. | 45-700-IG1-S10-DD-5A | Cage 06402 |
Nothing similar to this part number was found in our inventory
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.