single pole type
0.220in. and 0.280in.
2.189in.
0.750in.
metal
1.160in. and 1.220in.
1.796in. and 1.828in.
moderately rugged
2.000in.
1
air
2 threaded hole
general purpose warehouse
32
10.0 amperes ac single location and 10.0 amperes dc single location
205.0 ac single location and 30.0 dc single location
3500.0 ac single location and 6000.0 dc single location
overcurrent single location
thermal single location
time delay single location
138.0 single location
manual
trip free
1 PUSH-Pull
TRIP-Reset
at pole one
series trip single location
0.138in. ⁓9/64"
15.000 at 200 pct single location and 55.000 at 200 pct single location
fungus resistant and moisture resistant
25.0 deg celsius single location
400.0 single location
0.250 pounds
81349-MIL-C-5809 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
unc
2 tab w/screw
96906-MS25244 government standard
1EA
Unc
32
Schedule B number: 8536200040
nmfc 061300
Automatic circuit breakers, for a voltage not exceeding 1,000 v
FSC 5925 ⁓ Circuit breakers
Excluding relays.
unc thread series 32 thread quantity per inch
1. | AS25244 | Cage 81343 |
2. | AS58091 | Cage 81343 |
3. | MS25244-P-10 | Cage 81343 |
4. | BACC18J10A | Cage 08903 |
5. | 104-210-102 | Cage 77342 |
6. | BACC18J10A | Cage 81205 |
7. | MS25017-10 | Cage 66195 |
8. | 2010B | Cage 79405 |
9. | 1710CB | Cage 79405 |
10. | MIL-C-5809 | Cage 81349 |
11. | MS25244-P-10 | Cage 96906 |
12. | C5809BMS2505-10 | Cage 81349 |
13. | BACC18J-10 | Cage 81205 |
Nothing similar to this part number was found in our inventory
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.