Serving our customers with quality and safety first.
MULTIPOLE-Single actuator type
0.495in.
2.000in.
1.515in.
plastic
1.530in.
0.750in.
at 6 oclock
0.656in.
0.138in.
2.232in.
2
1 threaded bushing w/panel seal
32
50.0 amperes dc first location
36.0 dc second location
32.0 dc first location
1500.0 dc first location
overcurrent first location
overvoltage second location
magnetic first location
magnetic second location
instantaneous second location
time delay first location
125.0 first location
150.0 second location
manual
trip free
1 toggle
TRIP-Reset
at pole two
series trip first location
series trip second location
0.500in. ⁓1/2"
0.180 at 200 pct first location and 1.800 at 200 pct first location
un
4 tab w/screw
1EA
Un
32
Schedule B number: 8536200040
nmfc 061300
Automatic circuit breakers, for a voltage not exceeding 1,000 v
FSC 5925 ⁓ Circuit breakers
Excluding relays.
un thread series 32 thread quantity per inch
1. | UPGN66-8254-1 | Cage 81541 |
Nothing similar to this part number was found in our inventory
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.