Datasheet. 10607304-1 specification

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

MULTIPOLE-Multiple actuator type

Body Length
A measurement of the longest dimension of the body,in distinction from width.

2.631in.

Body Width
A measurement taken at right angles to the length of the body,in distinction from thickness.

2.187in.

Case Material
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.

plastic

Center To Center Distance Between Terminals Parallel To Length
The center to center distance between terminals parallel to the length of the item.

1.422in. and 1.452in.

Center To Center Distance Between Terminals Parallel To Width
The center to center distance between terminals parallel to the width of the item.

0.860in. and 0.890in.

Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
The distance between centerlines of mounting facilities parallel to the length of the item.

1.797in. and 1.827in.

Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
The distance between centerlines of mounting facilities parallel to the width of the item.

0.860in. and 0.890in.

Fragility Factor
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.

moderately rugged

Mounting Surface To Terminal End Distance

2.422in. and 2.452in.

Pole Quantity
The number of poles included in the item.

3

Arc Quenching Method
The means of quenching an arc.

air

Mounting Facility Type And Quantity
Indicates the type and number of facilities by which the item is mounted.

6 threaded hole

Storage Type
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.

general purpose warehouse

Thread Quantity Per Inch
The number of threads on the item per linear inch measured on a line parallel to the thread axis.

32

Maximum Continuous Load Current Rating Per Pole
The maximum current load that each pole is rated to carry continuously.

60.0 amperes ac all locations and 60.0 amperes dc all locations

Operating Voltage Type And Rating Per Pole In Volts
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.

115.0 ac all locations and 30.0 dc all locations

Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.

2500.0 ac all locations and 6000.0 dc all locations

Circuit Protection Type
Indicates the type of electrical condition that will cause the device to trip.

overcurrent all locations

Trip Release Method
The means by which the trip mechanism is released.

thermal all locations

Trip Release Characteristic
Denotes the type of trip release action.

time delay all locations

Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.

138.0 all locations

Reset Method
The means provided to reposition the mechanism so that the device is ready to function.

manual

Main Contact Tripping Mechanism Type
Indicates the type of mechanism provided for tripping main contacts.

trip free

Manual Actuator Type And Quantity
Indicates the type and number of actuators provided for manual control.

3 PUSH-Pull

Actuator Function
Denotes the action imparted by actuator operation.

TRIP-Reset

Actuator Position Designation
An indication of the designated position of the actuator.

at each pole

External Actuator Linkage Arrangement
Indicates the arrangement of the externally connected actuators.

one, two, and three linked

Internal Trip Release Configuration
The basic internal electrical configuration of the trip mechanism.

series trip all locations

Nominal Thread Size
A designation that is used for the purpose of general identification of the thread.

0.138in. ⁓9/64"

Trip Delay Time In Seconds Per Rated Continuous Current
The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.

15.000 at 200 pct all locations and 55.000 at 200 pct all locations

Inclosure Protection Type For Which Designed
Indicates the type of protection for which the inclosure is designed.

general purpose

Trip Release Ambient Temp Rating
The temperature of the medium surrounding the trip release at which it can be operated continuously.

25.0 deg celsius all locations

Frequency In Hertz
The cycles per second /hertz/ of the alternating current.

400.0 all locations

Unpackaged Unit Weight
The measured weight of an item unencumbered by packaging or packing material.

0.625 pounds

Precious Material And Location
An indication of the precious material and its location in the item.

contact surfaces silver

Precious Material
Identification of the precious material contained in the item.

silver

Thread Series Designator
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unc

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

6 tab w/screw

Answers.

What quantity is this sold in?

1EA

What class is the thread series?

Unc

What is the thread quantity per inch?

32

What is the NSN for 10607304-1?

5925-00-883-3842

How is this classified for shipping?

Schedule B number: 8536200040
nmfc 061300
Automatic circuit breakers, for a voltage not exceeding 1,000 v

What's the federal classification of 10607304-1?

FSC 5925 ⁓ Circuit breakers

Excluding relays.

NSN 5925-00-883-3842 CIRCUIT BREAKER

unc thread series 32 thread quantity per inch

NIIN
008833842
NIIN Date
01/01/62
Schedule B
8536200040 
Name Code
00136
FIIG
A030A0
Item Weight
0.000lbs
Item Dimensions
--
QUP
Historical Price
$802.48 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Contains silver
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 940-003-60 Cage 76374

Major End Users Countries and entities

  • - Defense Logistics Agency 

Availability for 10607304-1 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other circuit breakers with similar characteristics

Nothing similar to this part number was found in our inventory

10607304-1 / Circuit breakerWhat is the formal definition of this item?

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.