TPL270R

TPL270R Circuit Breaker Box

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. TPL270R specification

Hazardous Locations/environmental Protection
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.

general PURPOSE-Nema type 1

Overall Depth
An overall measurement between specified points of an item,in distinction from height.

4.406in.

Center To Center Distance Between Mounting Facilities Parallel To Width
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.

5.000in.

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

9.999in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

7.062in.

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.250in.

Center To Center Distance Between Mounting Facilities Parallel To Height
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the height.

7.000in.

Standard Mounting Pattern Designator
A designation of the standard mounting facility arrangement provided.

4 POINT-Rectangular

Entrance Diameter Numeric Designator
A numeric designation which identifies the nominal diameter of the entrance/s/ provided on the item.

0.500/0.750/1.000

System For Which Designed
Indicates the type of system in which the item is designed to be used.

three wire single phase

Mounting Method
The means of attaching the item.

unthreaded hole

Main Line Maximum Current Rating In Amps
The maximum current rating of the main line,expressed in amperes.

70.0

Main Line Maximum Ac Voltage Rating In Volts
The maximum alternating current voltage rating of the main line,expressed in volts.

240.0

Ground Connection Type For Which Designed
Indicates the type of ground connection for which the item is designed.

solid

Circuit Breaker Type And Quantity
Indicates the type and number of circuit breakers provided.

2 single pole

Circuit Breaker Current Rating In Amps
The maximum electrical current which the circuit breaker will carry without interrupting the circuit,expressed in amperes.

30.0

Entrance Type And Quantity
Indicates the type and number of entrances provided.

11 four concentric knockout

Material
The chemical compound or mechanical mixture properties of which the item is fabricated.

steel

Surface Treatment
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.

paint

Style Designator
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.

rectangular, flush mounting

Answers.

What quantity is this sold in?

1EA

What is the style?

Rectangular, flush mounting

What material is the circuit breaker box made of ?

Steel

What is the overall width?

7.062 inches

What is the NSN for TPL270R?

5925-00-406-9804

How is this classified for shipping?

Schedule B number: 8538907020
nmfc 061300
Automatic circuit breaker parts for headings 8535, 8536 or 8537

What's the federal classification of TPL270R?

FSC 5925 ⁓ Circuit breakers

Excluding relays.

NSN 5925-00-406-9804 CIRCUIT BREAKER BOX

rectangular, flush mounting paint surface treated 7.062" overall width

NIIN
004069804
NIIN Date
04/27/70
Schedule B
8538907020 
Name Code
19365
FIIG
A17600
Item Weight
1.500lbs
Item Dimensions
--
QUP
Historical Price
$70.45 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. TL270RH Cage 60969
2. TRP270R2S Cage 60969

Major End Users Countries and entities

  • - Department of The Army 
  • - Department of The Navy 

Availability for TPL270R A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other circuit breaker boxs with similar characteristics

Nothing similar to this part number was found in our inventory

TPL270R / Circuit breaker boxWhat is the formal definition of this item?

An enclosure which includes, mounts, and protects one or more circuit breakers. it is designed for and may include a cover and such accessories as mounting hardware, brackets, and conduit fittings. may include terminal boards and/or bus conductors used as a convenience for terminating the circuit breakers. may include handle tie bars. it is usually used as a load center for the protection of certain electrical devices such as water heaters, motors, etc., or as a service center for homes or offices. for boxes which include only switches, jacks, fuseholders, terminals and/or terminal boards or fuseholders, or any combination of these devices, see switch box; jack box; terminal box; and distribution box. for boxes designed to mount and protect but do not include circuit breakers, see circuit breaker box subassembly. see also interconnecting cabinet; panel, power distribution; junction box; and cabinet, electrical equipment.