FAE36100S

FAE36100S Circuit Breaker Box

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. FAE36100S specification

Hazardous Locations/environmental Protection
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.

general PURPOSE-Nema type 1

Overall Depth
An overall measurement between specified points of an item,in distinction from height.

3.812in.

Center To Center Distance Between Mounting Facilities Parallel To Width
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.

13.500in.

Overall Height
The distance measured in a straight line from the bottom to the top of an item.

14.531in.

Overall Width
An overall measurement taken at right angles to the length of an item,in distinction from thickness.

7.875in.

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.344in.

Center To Center Distance Between Mounting Facilities Parallel To Height
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the height.

7.031in.

Standard Mounting Pattern Designator
A designation of the standard mounting facility arrangement provided.

4 POINT-Rectangular

System For Which Designed
Indicates the type of system in which the item is designed to be used.

three wire three phase

Mounting Method
The means of attaching the item.

unthreaded hole

Main Line Maximum Current Rating In Amps
The maximum current rating of the main line,expressed in amperes.

100.0

Main Line Maximum Ac Voltage Rating In Volts
The maximum alternating current voltage rating of the main line,expressed in volts.

600.0

Circuit Breaker Type And Quantity
Indicates the type and number of circuit breakers provided.

1 triple pole

Circuit Breaker Current Rating In Amps
The maximum electrical current which the circuit breaker will carry without interrupting the circuit,expressed in amperes.

100.0

Circuit Breaker Identification
The specification,standard,or manufacturers identification number or symbol used to identify the circuit breaker.

NEF62100R

Circuit Breaker Manufacturer Code
The identifying numeric code of the originator that controls or manufactures the circuit breaker.

77176

Material
The chemical compound or mechanical mixture properties of which the item is fabricated.

steel

Surface Treatment
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.

paint

Style Designator
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.

rectangular, flush mounting

Answers.

What quantity is this sold in?

1EA

What is the style?

Rectangular, flush mounting

What material is the circuit breaker box made of ?

Steel

What is the overall width?

7.875 inches

What is the NSN for FAE36100S?

5925-00-726-4460

How is this classified for shipping?

Schedule B number: 8538907020
nmfc 063160
Automatic circuit breaker parts for headings 8535, 8536 or 8537

What's the federal classification of FAE36100S?

FSC 5925 ⁓ Circuit breakers

Excluding relays.

NSN 5925-00-726-4460 CIRCUIT BREAKER BOX

rectangular, flush mounting paint surface treated 7.875" overall width

NIIN
007264460
NIIN Date
01/01/60
Schedule B
8538907020 
Name Code
19365
FIIG
A17600
Item Weight
14.000lbs
Item Dimensions
--
QUP
Historical Price
$544.33 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. NEF62100RAND1100 Cage 77176

Major End Users Countries and entities

  • - Department of The Navy 

Availability for FAE36100S A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
Rating variable 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
063160 SWITCH BOXES/ELEC ENCLOSURES 
UFC (universal freight code)
35205 

Similar by Design Other circuit breaker boxs with similar characteristics

Nothing similar to this part number was found in our inventory

FAE36100S / Circuit breaker boxWhat is the formal definition of this item?

An enclosure which includes, mounts, and protects one or more circuit breakers. it is designed for and may include a cover and such accessories as mounting hardware, brackets, and conduit fittings. may include terminal boards and/or bus conductors used as a convenience for terminating the circuit breakers. may include handle tie bars. it is usually used as a load center for the protection of certain electrical devices such as water heaters, motors, etc., or as a service center for homes or offices. for boxes which include only switches, jacks, fuseholders, terminals and/or terminal boards or fuseholders, or any combination of these devices, see switch box; jack box; terminal box; and distribution box. for boxes designed to mount and protect but do not include circuit breakers, see circuit breaker box subassembly. see also interconnecting cabinet; panel, power distribution; junction box; and cabinet, electrical equipment.