212-62-0900PC9

212620900PC9 Box Switch

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 212-62-0900PC9 specification

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

w/ front operator

Body Length
A measurement of the longest dimension of the body,in distinction from width.

13.750in.

Body Width
A measurement taken at right angles to the length of the body,in distinction from thickness.

9.062in.

Body Height
A measurement from the bottom to the top of the body,in distinction from depth.

9.781in.

Unthreaded Mounting Hole Diameter
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.

0.438in.

Maximum Voltage Rating In Volts
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.

500.0 ac and 500.0 dc

Mounting Method
The means of attaching the item.

unthreaded hole

Features Provided
Those features,not otherwise specified,which may be required for proper functioning of the item.

neutral terminal

Nonpile-up Contact Arrangement
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.

2 pole, single throw, double make, both positions maintained single switch unit

Contact Load Current Rating At Maximum Rated Voltage
The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.

200.000 amperes resistive dc and 200.000 amperes resistive ac

Special Features
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.

12 mtg holes irregular spaced

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

4 threaded stud

Answers.

What quantity is this sold in?

1EA

What is the NSN for 212-62-0900PC9?

5930-00-538-2545

How is this classified for shipping?

Schedule B number: 8536908085
nmfc 061300
Electrical apparatus for switching or protecting electrical circuits, or for making connection to/ in electrical circuits,for a

What's the federal classification of 212-62-0900PC9?

FSC 5930 ⁓ Switches

Excluding switchgear.

NSN 5930-00-538-2545 SWITCH,BOX

12 mtg holes irregular spaced

NIIN
005382545
NIIN Date
01/01/63
Schedule B
8536908085 
Name Code
02636
FIIG
A053A0
Item Weight
0.000lbs
Item Dimensions
--
QUP
Historical Price
$417.98 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
Metal content unknown
Enviromental
N/A
Electrostatic ESD & EMI
No ESD or EMI sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. 212-62-0901PC17 Cage 80064
2. 212-62-0903PC17 Cage 80064
3. 212-62-705WPC9 Cage 80064
4. 212-62-716WALT2PC17 Cage 80064
5. 212-62-717ALT4PC17 Cage 80064
6. 212-62-717WALT3WPC17 Cage 80064
7. 212-62-705ALT8PC9 Cage 80064
8. 214-6201-776894REV2PC9 Cage 80064
9. 214-6201-776895REV2PC17 Cage 80064
10. 240-6201-1035120PC8 Cage 80064
11. 240-6201-1035122PC9 Cage 80064
12. 253-62-0900PC9 Cage 80064
13. 253-62-0901PC17 Cage 80064
14. 313-62-702WPC9 Cage 80064
15. 313-6201-60521PC12 Cage 80064
16. 313-6201-60521WPC12 Cage 80064
17. 319-3101-1183779LINE83SH1 Cage 80064
18. 319-3101-1183779LINE93SH2 Cage 80064
19. 319-6201-1183784ALT1PC4 Cage 80064
20. 319-6201-1183785ALT1PC5 Cage 80064
21. 337-6201-231724WPC9 Cage 80064
22. 337-6201-231725PC12 Cage 80064
23. 337-6201-231725WPC12 Cage 80064
24. 340-6000-1002475ALT1LINE274 Cage 80064
25. 340-6000-1002475ALT1LINE280 Cage 80064
26. 340-6201-1002395PC4 Cage 80064
27. 340-6201-1002396PC5 Cage 80064
28. 340-6201-937457PC5 Cage 80064
29. 343-6201-839806PC4 Cage 80064
30. 343-6201-839807PC5 Cage 80064
31. 346-6201-839603PC4 Cage 80064
32. 346-6201-839604ALT1PC5 Cage 80064
33. 347-6201-232279PC12 Cage 80064
34. 347-6201-237278PC9 Cage 80064
35. 361-6201-539847PC17 Cage 80064
36. 361-6201-539848PC9 Cage 80064
37. 363-6201-807023REVAPC4 Cage 80064
38. 363-6201-807023REVAPC5 Cage 80064
39. 381-62-1162CS1PC8 Cage 80064
40. 381-62-1162PC8 Cage 80064
41. 381-6201-67601PC8 Cage 80064
42. 403-6201-984861ALT4PC7 Cage 80064
43. 417-6201-69035ALT13PC8 Cage 80064
44. 417-6201-984827ALT7PC7 Cage 80064
45. 418-6201-1194050PC4 Cage 80064
46. 425-6201-723315PC7 Cage 80064
47. 435-6201-232060PC10 Cage 80064
48. 435-6201-232061PC12 Cage 80064
49. 478-6201-723899PC7 Cage 80064
50. 484-6201-722149PC8 Cage 80064
51. 31668 Cage 81316
52. 5939-381PC8 Cage 81316
53. 5903-381PC8 Cage 81316
54. 5903-417PC8 Cage 81316
55. 5903-478PC7 Cage 81316
56. 5903-484PC8 Cage 81316
57. 5939-417PC8 Cage 81316
58. 7209-425PC7 Cage 81316
59. 559E32PC8 Cage 14921
60. 559E36PC8 Cage 14921
61. G378-1ALS Cage 79443
62. G378-1LS Cage 79443
63. G378PC1T062 Cage 79443
64. MD378-1ALS Cage 79443
65. MD378-1LS Cage 79443
66. 2073-08ALT8PC9 Cage 96169
67. 2073-08PC9 Cage 96169
68. 2073-09PC17 Cage 96169
69. 2073-83PC17 Cage 96169
70. 2073-86ALT4PC17 Cage 96169
71. 2473-08WPC9 Cage 96169
72. 2473-09PC12 Cage 96169
73. 2473-09WPC12 Cage 96169
74. 2473-10WPC9 Cage 96169
75. 2473-11PC12 Cage 96169
76. 2473-11WPC12 Cage 96169
77. 2473-138PC10 Cage 96169
78. 2473-139PC12 Cage 96169
79. 2073-86PC17 Cage 96169
80. 2273-08PC9 Cage 96169
81. 2273-506PC17 Cage 96169
82. 2273-507PC9 Cage 96169
83. 2273-83PC17 Cage 96169
84. 2273-86ALT3WPC17 Cage 96169
85. 2473-45PC9 Cage 96169
86. 2473-46PC12 Cage 96169
87. 2773-11PC4 Cage 96169
88. 2773-12PC5 Cage 96169
89. 2773-33PC4 Cage 96169
90. 2773-34PC5 Cage 96169
91. 3395-02LINE83SH1 Cage 96169
92. 3395-02LINE93SH2 Cage 96169
93. 3373-09ALT1PC4 Cage 96169
94. 3373-10ALT1PC5 Cage 96169
95. 3873-13PC5 Cage 96169
96. 3873-21PC4 Cage 96169
97. 3873-65PC5 Cage 96169
98. 3895-03ALT1LINE274 Cage 96169
99. 3895-03ALT1LINE280 Cage 96169

Major End Users Countries and entities

  • - Brazil 
  • - Spain 
  • - Italy 
  • - Turkey 

Availability for 212-62-0900PC9 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
No special type of cargo code applicable 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Electrical appliances, small 
NMFC (national motor freight code)
061300 CIRCUIT BREAKER/SWITCH NOI 
UFC (universal freight code)
34410 

Similar by Design Other switchs with similar characteristics

Nothing similar to this part number was found in our inventory

212-62-0900PC9 / Switch,boxWhat is the formal definition of this item?

A switch designed with its actuator extending from the box which incloses the circuit elements. the door or cover of the box is designed so that it may be readily opened or removed, thus providing relatively easy access to the circuit elements. the item is commonly designated as a safety switch or entrance switch. may be fusible and may have interlocking device.