585F311PC9

585F311PC9 Nonwire Wound Variable Resistor

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

Datasheet. 585F311PC9 specification

Section Quantity
The number of individual elements.

1

Body Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.

cylindrical bushing mounted

Reliability Indicator
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.

not established

Overall Length
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.

1.062in. and 1.312in. ⁓1-5/16"

Body Diameter
The length of a straight line which passes through the center of the body,and terminates at the circumference.

1.032in. and 1.156in.

Shaft Diameter
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.

0.248in. and 0.251in.

Shaft Length
A measurement of the longest dimension of the shaft,in distinction from width.

0.594in. and 0.656in.

Mounting Bushing Length

0.485in. and 0.515in.

Body Length
A measurement of the longest dimension of the body,in distinction from width.

0.468in. and 0.656in.

Overall Diameter
A measurement of the longest straight line across a circular cross-sectional plane.

1.515in. ⁓1-33/64"

Shaft Style
The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.

round, slotted

Actuator Type
Indicates the type of facility or arrangement provided for moving the variable contact(s).

single shaft

Maximum Starting Torque
The maximum amount of turning force required to initiate the actuator movement.

6.00 INCH-Ounces

Maximum Stop Torque
The maximum amount of turning force that can be applied through the operating shaft with0ut damage to the stops.

128.00 INCH-Ounces

Nonturn Device Location
Indicates the location of a mechanical device which prevents the turning of the item on its mounted surface,expressed by the twelve hour clock designation.

at 9 oclock

Nonturn Device Radius
The linear measurement of the distance from the actuator centerline to the centerline of the nonturn device.

0.515in. and 0.547in.

Screw Thread Diameter
The length of a straight line which passes through the center of a coaxial cylinder which would bound the crest of an external thread or the root of an internal thread.

0.375in.

Screw Thread Series Designator
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.

unef

Screw Thread Quantity Per Inch
The number of screw threads on the item per linear inch measured on a line parallel to the thread axis,including incomplete threads.

32.0

Terminal Location
The position of the terminal/s/ for making connection to an item.

radially positioned over less than half the circumference

Mounting Method
The means of attaching the item.

locking bushing

Electrical Resistance Per Section
A measure of the opposition to the flow of direct or alternating current per section.

1.0 kilohms single section

Rotary Actuator Travel In Angular Deg
The measurement of the rotary mechanical motion of the actuating shaft of an item,expressed in degrees.

309.0 and 320.0

Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power
The ambient temperature at which the power dissipation of each section is derated to zero percent of the full rated power.

120.0 single section

Power Dissipation Rating Per Section In Watts
The maximum amount of electrical energy that can be expended per section,expressed in watts.

2.0 free air single section

Resistance Tolerance Per Section In Percent
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.

-10.0/+10.0 single section

Actuator Travel Control Feature
The feature that controls the actuator travel.

stops

Ambient Temp In Deg Celsius Per Section At Full Rated Power
The ambient temperature,expressed in degrees celsius,of the medium surrounding each section at which it can be operated continuously at full rated power.

70.0 single section

Standard Taper Curve Per Section
The rate of change and distribution of resistance per section,in relation to the rotation of the control shaft,which establishes a standard taper curve designated by an alphabetic character and accepted for common usage.

a single section

Test Data Document
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.

81349-MIL-R-94 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .

Terminal Type And Quantity
Indicates the type and number of terminals for providing electrical connection.

3 tab, solder lug

Specification/standard Data
The document designator of the specification or standard which established the item of supply.

81349-MIL-R-94/5 government specification

Answers.

What quantity is this sold in?

1EA

What is the NSN for 585F311PC9?

5905-00-646-5958

How is this classified for shipping?

Schedule B number: 8533400080
nmfc 062960
Variable resistors, including potentiometers

What's the federal classification of 585F311PC9?

FSC 5905 ⁓ Resistors

Excluding resistance wire.

NSN 5905-00-646-5958 RESISTOR,VARIABLE,NONWIRE WOUND,

1.062" overall length

NIIN
006465958
NIIN Date
01/01/63
Schedule B
8533400080 
Name Code
37405
FIIG
A002A0
Item Weight
0.100lbs
Item Dimensions
--
QUP
Historical Price
$14.18 EA
DEMIL / ITAR
Uncontrolled item (Code A)
Hazmat
No hazard information available from HMIRS.
MSDS
N/A
Precious Metals
No precious metals
Enviromental
N/A
Electrostatic ESD & EMI
Has ESD sensitivity

Other Part Numbers Parts with same form, fit, and function by other manufacturers

1. JA1L040S102UC Cage 44655
2. MIL-R-94 Cage 81349
3. RV4NAYSA102A Cage 81349
4. RV4NAYS102A Cage 81349
5. 580004H102 Cage 28528
6. 55774 Cage 36378
7. RV4LAYSA102A Cage 81349
8. MILR94-5 Cage 81349
9. 0A109267-0045 Cage 27914
10. 11134-0013 Cage 27914
11. 8851769 Cage 19203
12. JA1L040S102UA Cage 01121
13. JLU1021SD4040 Cage 01121
14. 697157-102 Cage 14100
15. 240-6001PA Cage 49956
16. 317-101-002 Cage 07421
17. RV19 Cage 37338
18. RVP02 Cage 37338
19. RV4LAYSA102A Cage 44655
20. F811 Cage 57655
21. RVP02 Cage 57655
22. 317-101-008 Cage 07421
23. 4171786-207 Cage 82577
24. 9167404 Cage 18876
25. JAIL040S101UZ Cage 01121
26. RU4LAYSA102A Cage 01121
27. RV4LAYSA102A Cage 12697
28. 11210-008 Cage 12763
29. A700-1116 Cage 21269
30. JH21383 Cage 71450
31. 138-002-1021 Cage 95542
32. 3522 500 02988 Cage H0203
33. 25510 TYPE J Cage H3402
34. JA1M032S102UY Cage 01121
35. 50202-1021-02 Cage 79343
36. 50202-1021-02 Cage 93568
37. 41605-705-7 Cage K4556
38. RV4LAYSB102A Cage 81349
39. 25510 TYPE J Cage H3649
40. 4001-0054 Cage 28763

Major End Users Countries and entities

  • - National Aeronautics And Space Administration 
  • - National Aeronautics And Space Administration 
  • - Tennessee Valley Authority 
  • - Department of The Navy 
  • - Department of The Army 
  • - U.s. Marine Corps 
  • - Department of The Air Force 
  • - National Security Agency 
  • - Federal Aviation Administration 
  • - U.s. Coast Guard 
  • - Austria 
  • - Poland 
  • - Brazil 
  • - Spain 
  • - Singapore 
  • - Malaysia 
  • - Thailand 
  • - Australia 
  • - Canada 
  • - New Zealand 
  • - France 
  • - Germany 
  • - Republic of Korea 
  • - United Kingdom 
  • - Netherlands 
  • - Portugal 
  • - Italy 
  • - Norway 
  • - Greece 
  • - Turkey 
  • - Nato Maintenance And Supply Agency 

Major End Items End use applications

  • - An/glq 3 countermeasure set
  • - Test set,radio
  • - Motor-generator
  • - Terminal,telephone
  • - Generator set,diesel engine,trailer mounted
  • - Telephone set
  • - Receiver,radio
  • - Counter,electronic,digital readout
  • - Test set,navigation
  • - Generator,signal
  • - Oscilloscope
  • - Truck,utility
  • - Central,communications
  • - Indicator,azimuth-range
  • - Generator set,diesel engine,trailer mounted
  • - Radio terminal set
  • - Radio terminal set
  • - Electronic shop,semitrailer mounted
  • - Generator set,diesel engine
  • - Counter,electronic,digital readout
  • - Test set,radar
  • - Converter,single sideband
  • - Oscilloscope
  • - Generator set,diesel engine
  • - Oscilloscope

Availability for 585F311PC9 A member of our team will provide you with a price and availability quote

Request a Quote »

Shipping Information

Special Handling
Other or no special handling required (sh) 
LTL (less than a truck load rating)
77.5 
LCL (less than a car load rating)
Unknown
Special Cargo
Electrostatic sensitive device (esd) 
Air Freight (Minimum cargo door size required)
Shipment is not a consolidation and does not exceed 84 inches in any dimension. 
Customs Requirement Classification
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) 
Commodity (for shipments via water)
Communications/electronics, other than sigint/ew or comsec repair parts and components 
NMFC (national motor freight code)
062960 REOSTATS/PARTS NOI 
UFC (universal freight code)
35140 

Similar by Design Other resistors with similar characteristics

Nothing similar to this part number was found in our inventory

585F311PC9 / Resistor,variable,nonwire wound,What is the formal definition of this item?

A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. the functional tolerance (linearity), if given, of the output is greater than plus or minus 1 percent on linear outputs. specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. for items having manually positioned taps designed to be set and fixed prior to use, see resistor, adjustable. for items with step by step variation, see rheostat and resistor, step by step. for tandem-mounted items designed to function together as an attenuator (and rated accordingly), see attenuator, variable. excludes resistor (1), variable, wire wound, nonprecision; resistor (1), variable, nonwire wound precision; and resistor (1), variable, wire wound, precision.