1pdt; 3 amp at 115 vac; max input voltage 260 vac 50/60 hz; drop-out time 0.05 seconds max; automatic reset; 1.950 in. lg; 1.950 in. w; 3.250 in. h; plug in mtg; standard tube base
btime delay on 20 sec; interval time 40 sec; 2.125 in. lg; 1.469 in. w; 2.625 in. h; three 0.147 in. dia mtg holes spaced on the corners of an isosceles triangle, base 0.750 in., altitude 1.844 in.
input voltage range 18-32 vdc; input current drain 100 ma max; delay time 0.5 sec; output data 2pdt 28 vdc 115 vac 10 amp; hermetically sealed; 1.652 in. max lg; 1.532 in. max w; 2.417 in. h; four 0.138-32 in. thd mtg studs on 1.187 in. by 0.875 in. mtg centers
input voltage range 18-32 vdc; input current drain 100 ma max; delay time 10 sec; output data 2pdt 28 vdc 115 vac 10 amp; hermetically sealed; 1.652 in. max lg; 1.532 in. max w; 2.417 in. h; four 0.138-32 in. thd mtg studs on 1.187 in. by 0.875 in. mtg centers
ac line voltage 100-140 vac; 360-440 hz; max load current 10 amp; 2.250 in. lg; 1.750 in. w; 0.870 in. h; four 8-32 in. thd mtg holes spaced 1.870 in. by 1.000 in. mtc centers
input voltage: 120 vac, 50 or 60 hz; output data: 1pdt; 2 amp resistive at 120 vac or 28 vdc; trip point is factory set at 51.5 porm 0.5 hz or 61.8 porm 0.5 hz; operating temperature minus 25 deg f to plus 125 deg f; 3.875 in. lg; 3.500 in. w; 2.406 in. h; four 0.172 in. dia mtg holes on 3.500 in. by 3.000 in. mtg centers; enclosed in a sealed steel can
120 vac line voltage; 400 hz normal frequency; 400-450 hz adjustment frequency range; output contacts; one set normally open, one set normally closed; contact ratings; 2 amps resistive at 120 vac or 28 vdc; 3.500 in. lg; 3.875 in. w; 2.469 in. h; four 0.172 in. dia mtg holes on 2.750 in. by 3.500 in. mtg centers; six screw terminals
contact data: 1pdt, 2 amp at 30 vdc, 1 amp at 115 vac; input data: auxiliary 18-31 vdc, 105-125 vac 400 hz, control 10-31 vdc; fixed time delay on release 5 minutes; temperature range minus 55 deg c to plus 85 deg c; 2.491 in. max lg; .1542 in. max w; 2.093 in. max h; two 0.149 in. dia mtg holes spaced 2.090 in. c to c; hook terminals, hermetic seal 1.3 in. mercury
1pst; 1.0 oz max wt; input voltage range 18 to 32 vdc; continuous duty; contact current rating 0 to 150 ma max inductive load; time delay on pick-up 10 sec; shock resistant; hermetically sealed; vibration resistant; salt spray resistant; moisture resistant; 1.280 in. max lg; 0.410 in. max w; 0.695 in. max h; two 0.120 in. dia mtg holes spaced 1.062 in. c to c; eight wire hook terminals
6 amp; 200v peak; 890 ohms resistance; glass-filled nylon case; quick disconnect terminals; 8 vdc input; zero deg to plus 70 deg c, operating temperature range; 2.620 in. lg; 1.500 in. w; 1.460 in. h; two 0.190 in. dia mtg holes spaced 2.250 in. c to c
spstno; 4 amperes; 3 to 32 vdc input voltage; 2 to 55 vdc output voltage; 2.250 in. lg; 1.750 in. w; 1.125 in. h; screw terminals; two 0.172 in. dia mtg holes spaced 1.870 in. center to center
K250 volts ac line voltage; 25 amp load current; 5 volt dc input voltage; plastic blue case 2.700 in. lg max; 1.520 in. w max; 1.650 in. h max; two 0.190 in. dia mtg holes spaced 2.250 in. c to c
240 volt ac max line voltage; max load current 30 amps; 20 volt dc input voltage; plastic blue case 2.700 in. lg max; 1.520 in. w max; 1.650 in. h max; two 0.190 in. dia mtg holes spaced 2.250 in. c to c
input 120VAC60hz relaytime delay from 1.2 sec to 120 sec operating temp range minus 10 to plus 40 deg CEN2.782 in, 1.531 in l, 1.406 in wquick disconnect terminals
2pdt; 10 amp at 115 vac; input voltage 115 vac; 8 pin termination; adjustment knob; time range 6 to 300 seconds; 2.000 in. max lg; 1.562 in. max w; 4.000 in. max h
2pdt; 10 amp at 115 vac; input voltage 24 vdc; 8 pin termination; adjustment knob; time range 1 to 90 seconds; 2.000 in. max lg; 1.562 in. max w; 4.000 in. max h
vencapsulated, optically isolated, dc control, solid state relay with ac rated, normally open contacts; input data: control voltage range 3-32 vdc; max input current 9.5 ma dc at 13.0 vdc control voltage; output data: operating voltage 280 vrms max at 60 h; rated load current 2.5 amps max at power factor of 40 % with external filtor; operating temperature -30 deg c to +80 deg c; 2.250 in. lg; 1.750 in. w; 0.875 in. h; two 0.172 in. dia mtg holes spaced 1.875 in. c to c; screw terminals
0analog signal switching spstno; isolated; 50 milliamperes; 40 vac or 40 vdc; input voltage range 4 to 7 vdc; input current 22 milliamperes dc; 0.275 in. max lg; 0.370 in. max dia; 4 wire lead terminals; hermetically sealed; mtd by terminals
signal switching; spstno; isolated; 250 milliamperes; 40 vdc; input voltage range 4 to 7 vdc; input current 22 milliamperes dc; wire lead terminals; 0.275 in. max lg; 0.370 in. max dia; terminal mtd; hermetically sealed
ftime delay on operate 10 sec; input voltage 20 vdc to 32 vdc continuous; output data 1pst; switch closure to plus 28 vdc 150 ma; 0.920 in. lg; 0.410 in. max w; 0.810 in. h; track mtd; qualitylevel w
operating data, 18 to 32 vdc, 5 ma max, C0ntinuous; output data, spstno, 28 vdc, 250 ma max; timing action delay on operate fixed 2 sec; ambient temperature minus 55 deg c to plus 125 deg c; moisture resistance; 1.718 in. max lg; 0.485 in. max w; 1.300 in. h; two 0.150 in. wide mtg slots spaced 1.421 in. c to c
Used on next generation radar (nexrad). nsn restricted to use by nws depot team only; voltage rating 120 vac, 50/60 hz; contacts 0.5 amp inductive load; adjustable time delay 0.2 to 30 seconds; reset time on delay
contact data dpdt, 2 oamps at 120 ovac, input data 28 ovdc, operate time 3msecs, release time 2 msecs, dielectric strength between insulated points 1500 urms, operating temp 55c to 65c, senstive coils 55c to 75c, slodering temperature 270 c 518 f max for 5 seconds, 8 pin plug in, o/a dimentions 1.090 lg, 0.675 o/a high, mounting data standard octal eight pin plug in