Used on cable assembly w465 e/i fscm 31442. insulation resistance shall be 5000 megohms ; dielectric withstanding voltage shall be 1200 vac rms at sea level; current rating shall be 7.5 amps ; contact resistance shall be 0.010 ohms ; working voltage shall be 300 vac rms; when a of 10 pounds of force is axially applied, the contacts shall be retained in the insultor; contacts shall complete 500 mating cycles with no indication of degradation; operating temperature range shall be from -55 degrees c to +125 degrees c; insulators shall be made from glass filled diallyl phthalate; contacts shall be copper alloy; contact plating shall be 50 microinches of gold, type 1, grade c, over 50 microinches of nickel
Used on f-14a e/i fscm 80132. switch has double pole, double throw circuit with momentary engagement; operating temperature range -55 degrees c to +125 degrees c; four lamps required; enclosure shall be dripproof; removable lens; terminations are double turret, solder terminals, supplied hot solder dipped; panel thickness 0.060 - 0.080"
Used on f-14a e/i fscm 80132. switch has double pole, double throw circuit with momentary engagement; operating temperature range -55 degrees c to +125 degrees c; four lamps required; enclosure shall be dripproof; removable lens; terminations are double turret, solder terminals, supplied hot solder dipped; panel thickness 0.060 - 0.080"
Used on f-14a e/i fscm 80132. switch has double pole, double throw circuit with mometary engagement; operating temperature range -55 degrees c to +125 degrees c; four lamps required; enclosure shall be dripproof; removable lens; terminations are double turret, solder terminals, supplied hot solder dipped; panel thickness 0.060 - 0.080"