Hybrid Relays. 2,631 part numbers in this category

Home » Catalog » Electrical » Hybrid Relays (Page 9)
Part Number
NSN
NIIN
1001X
1001X
5945-01-308-8474
013088474
Used on used in shore time panel onboard 378 ft whec coast guard vessels. phase failure delay nom voltage 120 v, 60 hz; voltage drop-out 75% - 100% of nom voltage; adjustable; pickup to dropout differential 3% approx; operating temp -20/+70 deg c with drift of porm 1%; time delay 0 to 3.5 sec; output contacts one set normally openm; contact rating 10 amp at 28 vdc resistive; 10 amp at 230 vac resistive; solid state sensor w/relay output in a sealed can
10119292-101
10119292101
5945-01-298-7587
012987587
Used on f-15 tiss. 3.190" overall length 3.270" overall width vinput voltage, 115 vrms (porm 20 pct) ; freq 50/60/400 hz (porm 20 pct) ; input voltage band (vrms) 101.5/106.5; freq band 50/70 hz; output contact 3pdt; contact rating 28 vdc, 2 amps resistive, 0.75 amps inductive; contact life 100, 000 operations min.; contact resistance 0.075 ohms max; steel case enclosure; hermetically sealed
10119292-102
10119292102
5945-01-298-8955
012988955
Used on f-15 tiss. 3.190" overall length 3.270" overall width sinput voltage, 115 vrms (porm 20 pct) ; freq 50/60/400 hz (porm 20 pct) ; input voltage band (vrms) 108.0/118.0; freq 393/407 hz; output contact 3pdt; contact rating 28 vdc, 2 amps resistive, 0.75 amps inductive; contact life 100, 000 operations min.; contact resistance 0.075 ohms max; steel case enclosure; hermetically sealed
1037572-1
10375721
5945-01-304-1969
013041969
Used on alq99 ecp054. 1.718" overall length 0.530" overall width moderately rugged item; 0.830 cu. in.; wt 0.119 lbs; input voltage 20-30 vdc; contact current rating at max rated voltage:10 amps dc resistive, 8 amps inductive, 4 amps dc motor, 2 amps dc lamp; 8 solder hook terminals; polarity protection; fixed time delay select from 100 msec to 600 sec; recycle time 50 msec max; mtg:two 0.150 in. wd slotted holes, parallel to lg, c to c distance between holes 1.396/1.446 in.
15039-507-201
15039507201
5945-01-325-0470
013250470
Used on b-1b acft. 1.170" overall length 0.890-" overall width 0.509 cu. in.; moderately rugged; 10 wirelead terminals
1A2B2
1A2B2
5945-01-312-1087
013121087
C10 amp; solder hook terminals; 2.880 in. lg; 2.380 in. w; 1.620 in. h; 120 vac, 400 hz i/p; phase sequence a-b-c; four 0.173 in. dia holes spaced 2.500 in. parallel to lgth
412DV-0429
412DV0429
5945-01-312-2142
013122142
518-5947777 ITEM 1-4
5185947777ITEM14
5945-01-320-1571
013201571
902-75
90275
5945-01-322-7112
013227112
Used on a-6a/b/e acft dcn. 0.176 cu. in.; moderately rugged item; wt 14.17 grams; positive supply voltage must applied to pin 5; 1 amp resistive at 28 vdc; coil:5.0 vdc nom, resistance 45-55 ohms; operate time 2.0 ms max; release time 7.5 ms max; continous duty; 0.840 in. max lg; 0.420 in. max w; 0.500 in. max ht
BE4-810/U1A4N1
BE4810U1A4N1
5945-01-295-4564
012954564
Used on auto switching unit. 8moderately rugged item; nom freq 60 hz; system voltage 120 vac; voltage withstand:1.2 times continuous 1.5 times for 10 sec; contacts:240 vac, 15 amps noninductive.24 vdc 2.5 amps resistance; automatic reset; wt 1.32 lbs; 2 mtg holes spaced 2.360 in. apart
C300 ENA3
C300ENA3
5945-01-326-0769
013260769
CGB-38-78010M
CGB3878010M
5945-01-303-6109
013036109
Used on 4920-01-153-0991 cart,engine vacuum check. 2.406" overall length 1.781" overall width moderately rugged item; 17.556 cu. in.; contact rating 10 amps at 240 vac; coil voltage 120 vac; 1 to 10 minutes time delay on release; polarity protection; plug-in mtg
CS-050-1966-87
CS050196687
5945-01-323-1108
013231108
5 amp dpdt contacts; 3 phase; 3 wire input; phase sensitive
GR835SS2
GR835SS2
5945-01-326-1455
013261455
Used on idp cat iii. 0.176 cu. in.; moderately rugged item; coil voltage 9-12 vdc; operate time 2.0 ms; release time 7.5 ms; contact rating 1 amp resistance at 28 vdc; continous duty; 16 pin terminal, plug-in mtg; 0.840 in. max lg; 0.420 in. max w; 0.500 in. max ht; pin lgth 0.140/0.160 in.
KKU431A
KKU431A
5945-01-325-3589
013253589
M28776/03-029
M2877603029
5945-01-306-5512
013065512
0.043 cu. in.; moderately rugged item; failure rate 0.1 pct; low level to 1.0 amps; rated voltage 18 vdc; coil resistance 1.60 kilohms; 0.493 in. max ht; plug-in terminal, 9 wire leads; wt 4.26 grams
M28776/1-016L
M287761016L
5945-01-297-9946
012979946
0.280" overall length failure rate 3 pct per 10, 000 cycles; test data document A81349-mil-r-28776; contact voltage rating:1 amp at 28 vdc
M28776/1-019M
M287761019M
5945-01-296-4450
012964450
relay is designed to operate w/low
M28776/1-027P
M287761027P
5945-01-310-9443
013109443
Used on 1440-01-215-4868,armament system. failure rate 0.1 pct; coil rated 9 vdc, coil resistance 220 ohms; 9 wire lead terminals; 0.335 in. max dia; 0.280 in. max ht; 0.025 cu. in.; moderately rugged item; wt 2.6 grams
M28776/4-041P
M287764041P
5945-01-323-6946
013236946
1 amp; 8 wire lead terminals; 0.375 in. max lg; plug-in mtg; i/p voltage 5 vdc nom; 15 ms power interrupt
M28776/5-036M
M287765036M
5945-01-322-5935
013225935
18.632 cu. in.; moderately rugged; wt 766.0 grams; contacts 115 vac
M28776/6-001M
M287766001M
5945-01-294-5738
012945738
Used on f/tf-15a acft. 0.450" overall length 0.350" overall width moderately rugged item; 0.047 cu. in.; unit wt 0.03 kg; test data document A81349-mil-r-28776; load ratings:resistive 500 ma at 115 vac
M28776/6-004L
M287766004L
5945-01-307-7643
013077643
Used on navy equipment. lcontacts 28 vdc
M28776/7-001M
M287767001M
5945-01-294-4729
012944729
0.455" overall length 0.350" overall width moderately rugged item; 0.065 cu. in.; test data document A81349-mil-r-28776; load ratings:resistive 500 ma at 115 vac
M28776/7-004
M287767004
5945-01-307-7644
013077644
Used on navy equipment. 0.034 cu. in.; moderately rugged item; failure rate 1.0 pct; contact voltage 115 vac
M83726/1-106
M837261106
5945-01-313-8022
013138022
10 amps; polarized; three 0.150 in. w mtg slots on corners of isosceles triangle spaced 1.396 in. lg x 0.625 in. w; 1.025 in. max lg; 1.025 in. max w; 1.010 in. max h; i/p voltage 20-30 vdc; 500 ms power interrupt
M83726/23-5000W
M83726235000W
5945-01-305-3000
013053000
Used on c t 2 acgt mo. 7.696 cu. in.; moderately rugged item; 4pdt; 10 amps resistive, 8 amps inductive, 4 amps motor, 2 amps lamp at 28 vdc; time delay 0.500 sec; duty rating:continous; nom volatge 28 vdc; 14 solder hook terminals; 4 thded studs mtg; 2.062 in. max lg, 2.062 in. max wd; 1.810 in. max ht
M83726/28-1001P
M83726281001P
5945-01-325-1460
013251460
1.718" overall length 1.025" overall width three 0.150 in. mtg holes placed in an isosceles triangle, c to c distance between mtg facilities parallel to wdth 0.625 in.
M83726/28-1803S
M83726281803S
5945-01-311-9979
013119979
three 0.159 in. mtg holes spaced in an isosceles triangle; continous duty; 10 amps resistive; inductive 8 amps lamp, 2 amps motor; fixed time delay 0.1-500.0 sec; transients-80v; spike transients-porm 600v; 1.718 in. max lg; 1.025 in. max w; 1.010 in. max h; moderately rugged; 1.778 cu. in.
M83726/28-2002S
M83726282002S
5945-01-322-3205
013223205
1.718" overall length 1.025" overall width input 20-30 vdc; coil voltage 115-200 vac, 400 hz; contact current 10 amps ac
M83726/28-2403P
M83726282403P
5945-01-310-2107
013102107
1.698" overall length 1.005" overall width three mtg slots in an isosceles triangle spaced 1.396/1.446 in; rated 115 vac
M83726/28-3001S
M83726283001S
5945-01-315-4423
013154423
1.698" overall length 1.005" overall width 10 amps resistive at 115 vac
M83726/28-3002P
M83726283002P
5945-01-317-6606
013176606
4three slotted holes spaced in isosceles triangle, spaced 1.446 in. parallel to lg, 0.625 in. parallel to wdth; 10 amps; fixed time delay 30 sec; contacts 200 vac or 28 vdc; continous duty; 1.025 in. max w; 1.025 in. max lg; 1.010 in. max h; 1.061 cu. in.
M83726/28-3002S
M83726283002S
5945-01-293-4080
012934080
Used on helicopter. 1.698" overall length 1.005" overall width moderately rugged item; 2.324 cu. in.; wt 0.156 lbs; test data document A81349-mil-r-28726; load ratings:resistive 10 amps at 115 vac or 28 vdc; inductive 4 amps at 115 vac or 28 vdc; lamp 2 amps at 115 vac or 28 vdc; polarized; input voltage 20-30 vdc; solder hook terminals; three 0.150 in. mtg slots spaced on corners of isosceles triangle, base 0.615/0.635 in.
M83726/28-5001S
M83726285001S
5945-01-311-9980
013119980
three 0.150 in. mtg holes spaced on corners of isosceles triangle; 14 wire hook terminals; 10 amps; fixed time 0.1-500.0 sec; 1.025 in. max lg; 1.025 in. max w; 1.010 in. max h; 1.060 cu. in.
M83726/28-6002P
M83726286002P
5945-01-323-5366
013235366
1.718" overall length 1.025" overall width three 0.150 in. mtg holes placed in an isosceles triangle, c to c distance between mtg facilities parallel to wdth 0.625 in.
M83726/29-1001P
M83726291001P
5945-01-311-9279
013119279
1.025" overall length 1.025" overall width 10 amps resistive at 28 vdc; 8 amps inductive at 28 vdc; 4 amps motor at 28 vdc; 2 amps lamp at 28 vdc; input voltage 20-30 vdc; continous duty; 14 pin terminals; time delay 100 ms; 1.061 cu. in.; three slotted holes in an isoscels triang; le configuration, c to c distance between mtg facilities parallel to ht of triangle 1.446 in. nom, c to c distance parallel to wdth o.625 in. nom; moderately rugged
M83726/29-2001S
M83726292001S
5945-01-315-4424
013154424
10 amps resistive at 115 vac
M83726/29-3003S
M83726293003S
5945-01-325-5481
013255481
Used on fuel management. 1.718" overall length 1.025" overall width input 20-30v; 10 amps resistive; 8 amps inductive; 4 amps dc motor; 2 amps dc lamp; fixed time delay 300 sec; 14 solder hook terminals; 3 slotted holes in an isosceles triangle configuartion, c to c distance between mtg facilities parallel to wdth 0.615/0.635 in.
M83726/29-5000S
M83726295000S
5945-01-303-3530
013033530
1.698" overall length 1.005" overall width test data document A81349-mil-r-83726; 14 solder lug terminals; contact rating 10 amps resistive, 8 amps inductive, 4 amps motor load, 2 amps lamp load; input voltage 20-30 vdc polarized; power interrupt 500 msec; three 0.150 in. wd mtg slots on corner of isosceles triangle spaced 1.396 in. lg x 0.625 in. wd nom
M83726/29-8001S
M83726298001S
5945-01-321-7410
013217410
1.698" overall length 1.005" overall width time delay 0.9-8.0 sec; input voltage 20-30 vdc; continous duty; 14 solder hook terminals; 3.593 cu.in.; wt 0.156 lbs; three slotted holes on an isosceles triangle, c to c distance between mtg facilities parallel to ht of triangle 1.446 in. nom, c to c distance parallel to wdth 0.625 in. nom; moderately rugged
M83726/30-1001S
M83726301001S
5945-01-293-5929
012935929
Used on helicopter. 1.698" overall length 1.005" overall width moderately rugged item; 2.324 cu. in.; test data document A81349-mil-r-83726; load ratings:resistive 10 amps at 115 vac
M83726/30-5001P
M83726305001P
5945-01-310-6195
013106195
1.698" overall length 1.005" overall width three 0.150 in. w mtg slots spaced on corners of triangle spaced 1.396 in. lg x 0.625 in. w; 10 amps; plug-in terminals; input 20-30 vdc
PLA623A115
PLA623A115
5945-01-307-9828
013079828
Used on shelter t. 1.970" overall length 1.970" overall width 10.425 cu. in.; moderately rugged; contacts rated 28 vdc, 2 amps resistive, 0.75 amps inductive; 60 hz; encapsulated; mtg:4 thd studs; 14 solder hook terminals; 4 watts max power dissipation
PMA1623D(100/131)(52/68)(0.5/1.-
PMA1623D1001315268051
5945-01-303-0752
013030752
Used on ea6a/b-dcn. vmoderately rugged item; contact rating:resistive 10 amps ac, inductive 6 amps ac; coil rating 115 vac; 60 hz; 14 solder hook terminals; 4 unthd holes; glass to metal connector; time delay (pickup) 250 ms to 10 sec, (dropout) 250 ms to 10 sec
PMALCS
PMALCS
5945-01-303-9973
013039973
Used on ac controller part number 12090-100-1 onboard 378 ft whec coast guard vessels. 8.00 cu.in.; series pma power quality monitor is designed to provide 3 phase protection for motors
PQA-D612D(185-230)(56/64)(10/10-
PQAD612D18523056641010
5945-01-324-0692
013240692
10 amp 28 vdc contacts; 185 vac pickup, 230 vac dropout; freq 56-64 hz; 10 sec delay; 208 vac line to line operating voltage; 3 phase
RL-Y0023-001
RLY0023001
5945-01-306-2483
013062483
Used on lantirn mob s. 4.400" overall length 4.150" overall width 5 amps resistive at 120 vac
SCDRA012XXEDXA
SCDRA012XXEDXA
5945-01-295-0274
012950274
1.970" overall length 1.970" overall width moderately rugged item; 14.359 cu. in.; storage temp -30/+60 deg c; 10 amps resistive at 120 vac; knob adjustment; 0.035 sec min reset time; plug-in mtg; wt 0.250 lb
SLA-0276
SLA0276
5945-01-314-2348
013142348
Used on 4520-00-057-9832 duct type,portable heater. moderately rugged; 2 terminal strips; 4 in. lg; 4 in. w; 3 in. h; four 0.218 in. unthd holes spaced on 3.250 in. sq mtg ctrs; 190-270 vac; 3 phase; with led
Page: 9 ...