NSN 5905-00-005-2647 NIIN 000052647 — Non Wire Wound Variable Resistor

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5905-00-005-2647
5905000052647
Description:
RESISTOR,VARIABLE,WIRE WOUND,NON
NSN Assigned:
16-JUN-72
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy
Description

Shaft diameter: 0.03", shaft length: 0.04", round, slotted shaft.

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5905-00-005-2647 Specification Set by the OEM (see RNCC code 3)

Electrical Resistance Per Section CQCC:

500 ohms single section

Standard Taper Curve Per Section CSDL:

a single section

Mounting Method AXGY:

terminal

Terminal Location APXH:

rear end

Effective Electrical Rotation In Degree Angular Rotation AEFH:

9000

Mounting Facility Quantity AKPV:

1

Actuator Type AEFD:

single shaft

Shaft Style AEDX:

round, slotted

Body Width ADAT:

0.203in.

Body Length ADAQ:

0.375in.

Body Height ADAU:

0.375in.

Shaft Length ABXF:

0.04in.

Shaft Diameter ABWV:

0.03in.

Reliability Indicator AARG:

not established

Mounting Hole Diameter ABTB:

0.09in.

Body Style AAQL:

rectangular w/mounting hole/slot

Section Quantity AAPN:

1

Resistance Tolerance Per Section In Percent CRSS:

-5 to 5 single section

Ambient Temp In Deg Celsius Per Section At Full Rated Power CSDH:

85 single section

Actuator Travel Control Feature CRSX:

clutch

Rotary Actuator Travel In Angular Degree CQCK:

9000

Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power CQGN:

150 single section

Power Dissipation Rating Per Section In Watts CRGD:

0.5 free air single section

Terminal Type And Quantity TTQY:

3 wire lead

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
960528-6
Cage Code:
82577
RNCC:
3
RNVC:
2
DAC:
1
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
3280L797-501
Cage Code:
80294
RNCC:
5
RNVC:
2
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
37406
FIIG:
A002A0
Concept No.:
1
App. Key:
A
Cond. Code:
1
Status:
A
BODY STYLE RECTANGULAR W/MOUNTING HOLE/SLOT style nsn 5905-00-005-2647
BODY STYLE RECTANGULAR W/MOUNTING HOLE/SLOT style nsn 5905-00-005-2647
SHAFT STYLE ROUND, SLOTTED style nsn 5905-00-005-2647

Definition Definition of approved item name (AIN): "RESISTOR,VARIABLE,WIRE WOUND,NON"

A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus of minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see resistor, adjustable. For items with step by step variation, see rheostat and resistor, step by step. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see attenuator, variable. Excludes resistor (1), variable, nonwire wound, nonprecision; resistor (1), variable, nonwire wound, precision; and resistor (1), variable, wire wound, precision.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Q
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5905-00-005-2647 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
U
ESD:
B
ESD:
B
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) U

Precious metal content is unknown

Electrostatic Discharge (ESD) B

Represents items with esd sensitivity.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.