NSN 6635-01-257-3125 NIIN 012573125 — Radiographic Film

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6635-01-257-3125
6635012573125
Description:
FILM,RADIOGRAPHIC
NSN Assigned:
17-JUN-87
DEMIL:
NO
Shelf Life:
24 months
UOM:
1 PG
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6635-01-257-3125 Specification Set by the OEM (see RNCC code 3)

Width ABGL:

14.000in.

Length ABRY:

17.000in.

Base Material AESH:

plastic, polyester

Base Color AETF:

blue

Emulsion Sensitivity AKGW:

blue

Film Exposure Quantity AKHB:

1

Contrast Rating AKHZ:

high

Base Material Thickness AKKE:

0.004in.

Granule Size ARSE:

fine

Sensitized Coating Location BSMM:

both sides

Corner Cut Type CKWB:

round

Film Processing Type CXJT:

8l, special

Precious Material And Location PMLC:

emulsion silver

Precious Material And Weight PMWT:

0.040 silver grains, troy

Precious Material PRMT:

silver

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
IDUSTREX M M2
Cage Code:
19139
RNCC:
5
RNVC:
1
DAC:
E
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
848 2556
Cage Code:
19139
RNCC:
3
RNVC:
2
DAC:
E
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
145 8926
Cage Code:
19139
RNCC:
5
RNVC:
9
DAC:
E
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
INDUSTREX M CODE M2
Cage Code:
19139
RNCC:
5
RNVC:
9
DAC:
E
RNAAC:
ZZ
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
01914
FIIG:
T140-B
Concept No.:
App. Key:
BB
Cond. Code:
2
Status:
A

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
SPI No.:
SPI Rev.:
SPC Mkg:
LVL_A:
E
LVL_B:
Q
LVL_C:

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6635-01-257-3125 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
Y
PMIC:
S
ESD:
ESD:
ADPE:
0
CRITL:
X
Hazmat (HMIC) Y

Indicates information is in the hazardous materials information resource system (hmirs).

Precious Metals (PMIC) S

Item contains silver.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
S9G
SOS:
MMAC:
MCC:
Source of Supply (SOS) S9G

Defense supply center richmond, virginia 23297

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.