NSN 4820-00-375-8226 NIIN 003758226 — Globe Valve

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
4820-00-375-8226
4820003758226
Description:
VALVE,GLOBE
NSN Assigned:
01-JAN-61
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

4820-00-375-8226 Specification Set by the OEM (see RNCC code 3)

Nominal Pipe Size Accommodated AAAR:

1.000in. all ends

Flow Control Device ADQU:

disk

Bonnet Type ADSR:

inside screw

Bonnet Attachment Method ADST:

union

Renewable Seat Ring Type ADZH:

threaded

Maximum Operating Temp AEHZ:

550.0 deg fahrenheit 1st RESPONSE150.0 deg fahrenheit 2nd response

Connection Style AHNC:

socket with brazing ring all ends

Valve Operation Method AQLR:

manual

Connection Type AWLS:

unthreaded internal pipe 1st end

Features Provided CBBL:

bonnet packing

Maximum Operating Pressure CQGM:

300.0 pounds per square inch 1st RESPONSE600.0 pounds per square inch 2nd response

Material MATT:

steel corrosion resisting seat

Material Document And Classification MDCL:

QQ-C-390, alloy D4 fed spec single material response body

Media For Which Designed MEDA:

WATER-OIL-Gas 2nd response

Style Designator STYL:

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
260WS1
Cage Code:
63686
RNCC:
3
RNVC:
2
DAC:
6
RNAAC:
AX
Status:
A
MSDS:
SADC:
Part Number:
325-4900-954537ALTCPCV5200
Cage Code:
53711
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
AX
Status:
A
MSDS:
SADC:
Part Number:
325-4900-954537ALTCPCV5199
Cage Code:
53711
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
AX
Status:
A
MSDS:
SADC:
Part Number:
576-6700-1505182REVAPCV137
Cage Code:
53711
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
AX
Status:
A
MSDS:
SADC:
Part Number:
576-6700-1505182REVAPCV137
Cage Code:
80064
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
AX
Status:
A
MSDS:
SADC:
Part Number:
325-4900-954537ALTCPCV5199
Cage Code:
80064
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
AX
Status:
A
MSDS:
SADC:
Part Number:
325-4900-954537ALTCPCV5200
Cage Code:
80064
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
AX
Status:
A
MSDS:
SADC:
Part Number:
4268-181REVAPCV137
Cage Code:
96169
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
AX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
05485
FIIG:
A046B0
Concept No.:
1
App. Key:
AT
Cond. Code:
2
Status:
A

Definition Definition of approved item name (AIN): "VALVE,GLOBE"

A valve with one inlet and one outlet connection with outlet flow parallel to inlet flow. The flow is controlled by the action of a stem which lifts the disk perpendicularly off the center axis of its seat. The stem is at a 90 degree (1.5708 radians) angle to axis of flow. Excludes valve, stop-check; cock, shutoff, screw stem; and valve, solenoid.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.5000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

4820-00-375-8226 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
SMS
SOS:
MMAC:
MCC:
Source of Supply (SOS) SMS

Defense logistics agency, enterprise business systems

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.